Tube Channel Replacement - Quadra-Fire 31M-ACC-GT Owner's Manual

3100 wood stove series, advanced combustion control (acc)
Table of Contents

Advertisement

R
F. Tube Channel Assembly Replacement
Removing Tube Channel Assembly
1. Remove the right side shield by removing 2 screws in the
back using a Phillips head screw driver.
2. Remove 4 screws from channel access cover and remove
cover.
3. Locate 2 channel nuts inside of chamber and remove
using a 7/16 socket wrench. Slide out tube channel
assembly.
NOTE: Soak the bolts with penetrating oil for at least 15 min-
utes before trying to remove them.
Replacing Tube Channel Assembly
1. Slide the tube channel assembly into side of fi rebox and
insert each tube into the corresponding hole in the tube
channel rack starting with the back hole fi rst.
2. Make sure tube channel assembly is fl ush against the
side of the stove and secure with channel nuts.
3. Re-install channel cover and side shield.
Tube Channel Rack
Figure 35.1
March 2, 2007
SERVICE / MAINTENANCE TIP
In order to replace the tube channel assembly a clear-
ance of 19 inches (483mm) is required on the right side
of stove in order to remove the tubes with the stove in
place. If space is not available, the stove will have to be
disconnected from the chimney to proceed with the tube
replacement.
Channel
Channel Cover
Access
Screws (4)
Cover
Channel
Nuts (2)
Tube Channel
Assembly
7033-277C
3100 Wood Stove Series (ACC)
Remove
2 Screws
Side Panel
Page 35