E. Tube Channel Assembly
Removing Tube Channel Assembly
1. Remove the right side shield by lifting up on side
to remove.
2. Remove 4 screws from channel access cover and
remove cover.
3. Locate 2 channel nuts inside of chamber and
remove using a 7/16 socket wrench. Slide out tube
channel assembly.
NOTE: Soak the bolts with penetrating oil for at least 15
minutes before trying to remove them.
Replacing Tube Channel Assembly
4. Slide one gasket onto each tube.
5. Slide the tube channel assembly into side of firebox
and insert each tube into the corresponding hole in the
tube channel rack starting with the back hole first.
6. Make sure tube channel assembly is flush against the
side of the appliance and secure with channel nuts.
7. Re-install channel cover and side shield.
Tube Channel Rack
Figure 22.1
22
NOTE: Service Space
In order to replace the tube channel assembly a
clearance of 483mm is required on the right side of
appliance in order to remove the tubes with the appliance
in place.
If space is not available, the appliance will have to be
disconnected from the chimney to proceed with the tube
replacement.
Slide one gasket
over each tube
Channel
Access
Cover
7033-362C
Channel Cover
Screws (4)
Channel
Nuts (2)
Tube Channel
Assembly
Side Panel
Remove
2 Screws
11/21

Advertisement

Table of Contents
loading

Table of Contents