Quadra-Fire Millennium 31M-ACC-MBK Owner's Manual

3100 wood stove series automatic combustion control (acc)
Table of Contents

Advertisement

Quick Links

31M-ACC-MBK
Millennium Model
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Installation and service of this appliance should
be performed by qualifi ed personnel. Hearth &
Home Technologies recommends NFI certifi ed
professionals, or technicians supervised by an NFI
certifi ed professional.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafi re.com
Pour obtenir une traduction française de ce manuel, s'il vous
00
plaît contacter votre revendeur ou visitez www.quadrafi re.com
www.quadrafi re.com
3100 WOOD STOVE SERIES
Automatic Combustion Control (ACC)
Owner's Manual
Installation and Operation
Step Top Uni-Body Model
WARNING
NOTE
MODELS:
31ST-ACC
(Pedestal Model Shown)
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same
room as fi replace.
• Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or
other fl ammable materials.
• Keep clothing, furniture, draperies and other
fl ammable materials away.
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfi re and generate poisonous
gases (i.e. carbon monoxide).
7033-277N
Tested and
Listed by
C
OMNI-Test Laboratories, Inc.
31M-ACC-LE
Limited Edition
WARNING
HOT SURFACES!
Glass and other surfaces are
hot during operation AND cool
down.
WARNING
Portland
O-T L
Oregon USA
US
August 3, 2015

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire Millennium 31M-ACC-MBK

  • Page 1 Portland Tested and O-T L Oregon USA Listed by 3100 WOOD STOVE SERIES OMNI-Test Laboratories, Inc. Automatic Combustion Control (ACC) Owner’s Manual Installation and Operation MODELS: 31M-ACC-MBK 31ST-ACC 31M-ACC-LE Millennium Model Limited Edition Step Top Uni-Body Model (Pedestal Model Shown) WARNING WARNING If the information in these instruc-...
  • Page 2 Hearth & Home Technologies welcomes you to our tradi- our stoves, inserts and fi replaces. And yet we are old-fash- tion of excellence! In choosing a Quadra-Fire appliance, ioned when it comes to craftsmanship. Each unit is meticu- you have our assurance of commitment to quality, durabil- lously fabricated and surfaces are hand-fi...
  • Page 3: Table Of Contents

    3100 Wood Stove Series (ACC) Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. •...
  • Page 4: Section 1: Listing And Code Approvals

    (UM) 84-HUD, Mobile Home Firebox Size: 1.85 cubic feet Approved. Recommended Wood Length: 16 inches The Quadra-Fire 3100 Series Wood Stove (ACC) meets the Fuel Orientation: Front-to-Back U.S. Environmental Protection Agency’s crib wood emission Fuel Seasoned Cord Wood limits for wood heaters sold after May 15, 2015.
  • Page 5: Section 2: Getting Started

    3100 Wood Stove Series (ACC) Getting Started B. Fire Safety A. Design, Installation & Location Consider ations Consideration must be given to: To provide reasonable fi re safety, the following should be given serious consideration: • Safety • Convenience Install at least one smoke detector on each fl oor of your •...
  • Page 6: Negative Pressure

    3100 Wood Stove Series (ACC) C. Negative Pressure To minimize the affects of negative air pressure the following Draft is the pressure difference needed to vent appliances must be considered: successfully. Considerations for successful draft include: • Install the outside air kit. Install the intake on the •...
  • Page 7: Flue Draft Considerations

    3100 Wood Stove Series (ACC) F. Tools And Supplies Needed D. Flue Draft Considerations Location of the appliance and chimney will affect perfor- Before beginning the installation be sure that the following mance. As shown in Figure 6.1 on page 6 the chimney tools and building supplies are available.
  • Page 8: Typical Stove System

    3100 Wood Stove Series (ACC) H. Typical Stove Systems Stove system with masonry chimney consists of: • Stove • Chimney Connector (stove pipe) • Thimble • Masonry Chimney • Hearth Pad Floor Protection Figure 8.1 Masonry Chimney Stove system with prefabricated metal chimney consists of: Listed Termination Cap Storm Collar...
  • Page 9: Appliance Dimensions

    3100 Wood Stove Series (ACC) Dimensions and Clearances A. Appliance Dimensions NOTE: Flue Collar size is 6 inch (152mm) diameter (ID) 31M-ACC-MBK (Millennium Model 26-11/16 in. (668mm) 25 1/4 in. (641mm) 24-5/16 in. (618mm) 6-11/16 in. 9-15/16 in. 12-1/2 in. (170mm) (237mm) (318mm)
  • Page 10 3100 Wood Stove Series (ACC) Appliance Dimensions (Cont.) 31ST-ACC (Step Top Model with 31ST-ACC (Step Top Model with Pedestal) Queen Ann Legs) 25 in. (635mm) 12-1/2 in. 9-5/16 in. (318mm (237mm) 14-15/16 in. 19-1/16 in. (379mm) (484mm) 33-1/8 in. 10-15/16 in. 15-1/16 in.
  • Page 11: Clearances To Combustibles

    3100 Wood Stove Series (ACC) B. Clearances to Combustibles (UL and ULC) NOTE: A, C and F measurements are to center of fl ue INSTALLATION: Full Vertical or Horizontal with Vertical Rise SINGLE WALL PIPE - A, B, C and D dimensions are based off of standard 18” stove pipe clearances to combustibles or unit certifi ed clearances, whichever is greater Millennium/Limited Edition 18-1/4 [464]...
  • Page 12: Section 4: Installation Consideration A. Hearth Requirements

    3100 Wood Stove Series (ACC) Installation In Canada, similar fl oor protection must be provided 18 A. Hearth Protection Requirements inches (457mm) in front and 8 inches (203mm) from the sides and rear of the stove. *See exception. FLOOR PROTECTION: Floor protector must be non-com- *EXCEPTION: Non-combustible fl...
  • Page 13 3100 Wood Stove Series (ACC) Step-Top Uni-Body Model For the Step Top Pedestal Model In US installations, it is For the Step Top Leg Model In US installations, it is nec- necessary to install a fl oor protector of a minimum of 3/8 inch essary to install a fl...
  • Page 14: Alternate Floor Protection Calculation

    3100 Wood Stove Series (ACC) B. Calculating Alternate Floor Protection Material heat resistant material up to 350 F. Cut the pipe to the required length for your installation. Thermal Conductivity: k value • Phillips head screw driver The k value indicates the amount of heat (in BTU’s) that will fl ow in 1 hour through 1 square foot of a uniform material 1 inch thick •...
  • Page 15 3100 Wood Stove Series (ACC) Outside Air Kit Installation (cont.) WARNING 31M-ACC-LE A source of air (oxygen) is necessary in order for combus- Fire Risk. tion to take place. Whatever combustion air is consumed Asphyxiation Risk. by the fi re must be replaced. Air is replaced via air leakage Do not draw outside combustion air from: around windows and under doors.
  • Page 16: Blower Installation

    3100 Wood Stove Series (ACC) E. Adjusting The Blower Speed Control D. Blower (Optional) The blower speed control for this unit is adjusted at the factory, 1. Remove the 3 bolts (1/4”-20 Phillips head) on the outer and normally does not require further adjustment. skin at the bottom rear of appliance.
  • Page 17: Section 5: Chimney Requirements

    3100 Wood Stove Series (ACC) Chimney Requirements A. Venting Components B. Chimney Systems Chimney Connector: Prefabricated Metal Chimney • Must be minimum 6 inch (152mm) diameter (ID) high It is also known as fl ue pipe or stove pipe. The chimney temperature chimney listed to UL 103 HT (2100 F) or connector joins the stove to the chimney.
  • Page 18 3100 Wood Stove Series (ACC) Thimble Site constructed for masonry chimney installation: ceiling Components 13.5” below ceiling to top of opening • A minimum length of 12 inches [305mm] (longer for Wall or top of opening is a min.of thicker walls) of solid insulated factory-built chimney 4.5”...
  • Page 19: Installing Chimney Components

    3100 Wood Stove Series (ACC) Solid Pack Chimney with Metal Supports as a C. Installing Chimney Components Thimble (Cont’d) Chimney Connector Single wall connector or stove pipe. Min. Chimney Clearance to This must be at least 24 gauge mild steel or 26 gauge blue Wall Spacer and Min.
  • Page 20: Chimney Termination Requirements

    3100 Wood Stove Series (ACC) D. Chimney Termination Requirements NOTE: Follow manufacturers instructions for clearance, securing, • Chimney performance may vary. fl ashing and terminating the chimney. • Trees, buildings, roof lines and wind conditions affect performance. • Must have an approved and listed cap •...
  • Page 21: Section 6: Mobile Home

    3100 Wood Stove Series (ACC) Mobile Home Installation You must use a Quadra-Fire Outside Air Kit Part SparkArestor Cap OAK-ACC and (depending on fl oor installation), Part SRV7033-041 for installation in a mobile home. 1. An outside air inlet must be provided for combustion See Storm Collar page 14 &...
  • Page 22: Ars) Installation

    3100 Wood Stove Series (ACC) Appliance Set Up A. Pedestal Assembly and Ash Removal System (ARS) Installation for Step Top Uni-body NOTE: The Ash Removal System, must be installed fi rst before installing the pedestal. ARS Cover Included in Kit: Door assembly, door handle & magnet, ash drawer, fastener package.
  • Page 23: Leg Kit & Ash Removal System (Ars) Installation

    3100 Wood Stove Series (ACC) Pedestal and Ash Removal System (Cont.) Installing Pedestal Assembly 1. Remove screws on adapter and slide pedestal over adapter on bottom of stove. Figure 23.1. 2. Line up holes in sides of pedestal with holes in adapter. 3.
  • Page 24: Door Handle Assembly

    3100 Wood Stove Series (ACC) Finishing the ARS Installation C. Door Handle Assembly 1. Follow steps 1 through 3 on page 22. See also Figure 1. Install washer on door handle shaft. 22.2. 2. Slide door handle through door. 3. Install second washer(s) as shown. 4.
  • Page 25 3100 Wood Stove Series (ACC) The 31LE units are now being shipped with a tile panel securing clip on both sides of the units. Please remove and discard pins prior to use. (Fig. 25.3 and 25.4) Figure 25.3 Figure 25.1 Figure 25.4 Figure 25.2 Page 25...
  • Page 26: Section 8: Operating Instructions

    In order to 2. What To Do if Your Stove is Over-Firing improve the situation, we at Quadra-Fire have developed cleaner-burning wood stoves that surpass the requirements • Immediately close the door and air controls to reduce for emissions established by our governing agencies.
  • Page 27: Automatic Combustion Control (Acc)

    3100 Wood Stove Series (ACC) 2. Second Stage The second function of the Start-Up Air Control is operation The next stage of burning, the secondary stage, is the period of the rear air system. The rear air is used primarily during when the wood gives off fl...
  • Page 28: Burn Rates & Operating Effi Ciency

    3100 Wood Stove Series (ACC) 2. Burn Rate Air Control Start-Up Air Control all the way back until it stops (HI marker) and then pull forward until it stops. This activates This air supply enters at the upper front of the fi rebox, near the timer system (ACC).
  • Page 29: Baffl E & Blanket Placement

    3100 Wood Stove Series (ACC) INCORRECT POSITIONS Operate appliance on High Burn 15 minutes a NOTE: day to help keep fl ue/chimney clean. G. Correct Baffl e & Blanket Placement WARNING Fire Risk Firebox damage due to improper baffl e place- ment is not covered by warranty.
  • Page 30: Building A Fire

    3100 Wood Stove Series (ACC) H. Building A Fire Baffle Board even with front Before lighting your fi rst fi re in the stove: tube & resting on all tubes 1. Confi rm the baffl e is correctly positioned. It should be even with the front tube and resting on all tubes.
  • Page 31: Blower Operating Instructions

    3100 Wood Stove Series (ACC) J. Opacity (Smoke) I. Blower Operating Instructions NOTE: If your Quadra-Fire wood stove is equipped with an This is the measure of how cleanly your appliance is burn- ing. Opacity is measured in percent; 100% opacity is when...
  • Page 32: Maintaining & Servicing Appliance

    3100 Wood Stove Series (ACC) Maintaining & Servicing Your Appliance A. Quick Reference Maintenance Guide BAFFLE & BLANKET PLACEMENT INSPECT FIREBRICKS & ASH COVER (AFTER EACH CLEANING) Back of Firebox Ceramic Blanket Baffle Retainer Bracket Step Top Models Only Baffle Board Baffl...
  • Page 33: General Maintenance & Cleaning

    3100 Wood Stove Series (ACC) B. General Maintenance 2. Ash Removal System (ARS) Operating and Cleaning 1. Creosote (Chimney) Cleaning • Frequency: As necessary • By: Homeowner • Frequency: Every 2 months during heating season or as recommended by a certifi ed chimney sweep; more CAUTION frequently if chimney exceeds or is under 14-16 ft.
  • Page 34: Glass Replacement

    3100 Wood Stove Series (ACC) 3. Disposal of Ashes stain the glass and damage the fi nish on plated metal • Frequency: When ash is within 1-3/4 in. (44mm) of surfaces. firebox lip A portion of the combustion air entering the fi rebox is defl ected •...
  • Page 35: Firebrick Replacement

    3100 Wood Stove Series (ACC) Replace the door on the appliance. 10.1 10.1 Quadra-Fire stoves are equipped with ceramic super heat- 10.1 10.1 resistant glass, which can only be broken by impact or 10.1 10.1 misuse. Do not slam stove door or impact the glass. When 10.1...
  • Page 36: Baffl E Removal

    3100 Wood Stove Series (ACC) F. Snap Disc Replacement E. Baffl e Removal 1. Locate the snap disc bracket assembly at the bottom left 1. Remove all ash from the fi rebox, and extinguish all hot rear corner of the stove. Figure 36. 3 embers before disposal into a metal container.
  • Page 37: Tube Channel Replacement

    3100 Wood Stove Series (ACC) G. Tube Channel Assembly Replacement NOTE: Service Space In order to replace the tube channel assembly a clearance Removing Tube Channel Assembly of 19 inches (483mm) is required on the right side of stove 1. Remove the right side shield by removing 2 screws in the in order to remove the tubes with the stove in place.
  • Page 38: Section 10: Troubleshooting

    3100 Wood Stove Series (ACC) With proper installation, operation, and maintenance your wood stove will provide years of trouble-free service. If you do experience a prob- lem, this troubleshooting guide will assist a qualifi ed service person in the diagnosis of a problem and the corrective action to be taken. Troubleshooting Start Fire Problems Possible Cause...
  • Page 39: Exploded Drawing & Service Parts

    Reference Materials A. Exploded Drawing & Service Parts 31M-ACC Service Parts Millennium - Wood Stove Beginning Manufacturing Date: July 2006 Advanced Combustion Control (ACC) Ending Manufacturing Date: Active 31M-ACC-MBK (7/06 - Active), 31M-ACC-GT (7/06 - 10/06), 31M-ACC-NT (7/06 - 10/06) Part number list on following page.
  • Page 40 31M-ACC Service Parts Beginning Manufacturing Date: July 2006 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed Stocked in this manual may be ordered from an authorized dealer. at Depot ITEM DESCRIPTION...
  • Page 41: Service Parts

    31M-ACC Service Parts Beginning Manufacturing Date: July 2006 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed Stocked in this manual may be ordered from an authorized dealer. at Depot ITEM DESCRIPTION...
  • Page 42 Glass Frame Set 4 Pieces 832-0350 Gold Trim Doors 436-5350 Component Pack (Includes Spring Handles (1) 1/2” & (2) 1/4”, (2) Hinge Pins, Quadra-Fire Logo) Nickel Trim Doors 436-5360 Gasket, Glass Tape - Field Cut to Size 5 Ft 832-0460 Rope, Door, 3/4”...
  • Page 43: Millennium

    832-0250 Pre SN 0071959142 Hinge Pins, 1/2”, Nickel 430-5320 Hinge Pins, 1/2”, Black 7000-606/2 Post SN 0071959142 Gold 200-3180 Logo, Quadra-Fire Nickel 200-3240 Spring Handle, 1/2”, Gold 832-0620 Pre SN 0071959142 Spring Handle, 1/2”, Nickel 250-8330 Spring Handle, 1/2”, Black...
  • Page 44: Exploded Drawing & Service Parts

    B. Exploded Drawing & Service Parts 31ST-ACC Service Parts Beginning Manufacturing Date: Sept. 2006 Step Top - Wood Stove Ending Manufacturing Date: Active 31ST-ACC (Advanced Combustion Control) Part number list on following page. 03/15 Page 44 7033-277N August 3, 2015...
  • Page 45 31ST-ACC Service Parts Beginning Manufacturing Date: Sept. 2006 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor. . Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 46 31ST-ACC Service Parts Beginning Manufacturing Date: Sept. 2006 Ending Manufacturing Date: Active #14 Burn Rate Control Assembly #15 Leg Assembly #16 Pedestal Assembly 14.10 15.1 14.1 16.1 16.3 14.9 14.2 15.3 14.8 14.3 16.2 14.4 15.2 14.5 14.7 14.6 IMPORTANT: THIS IS DATED INFORMATION .
  • Page 47: Door Assembly

    31ST-ACC Service Parts Beginning Manufacturing Date: Sept. 2006 Ending Manufacturing Date: Active Fiber Handle Assembly Spring Handle Assembly #17 Door Assembly 17.1 17.4 17.3 17.5 17.2 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Stocked Home Technologies does not sell directly to consumers.
  • Page 48: Step Top

    Blower, Convection - Replacement Blower 812-4900 Channel, Ash Removal Step-Top 7033-172 Gold Trim Doors 436-5350 Component Pack (Includes Spring Handles (1) 1/2” & (2) 1/4”, (2) Hinge Pins, Quadra-Fire Logo) Nickel Trim Doors 436-5360 Gold 832-0250 Hinge Pins, 1/2” (Qty 2) Nickel 430-5320...
  • Page 49: Exploded Drawing & Service Parts

    3100 Wood Stove Series (ACC) C. Exploded Drawing & Service Parts 31M-ACC-LE Service Parts Beginning Manufacturing Date: Sept. 2014 Ending Manufacturing Date: Active Part number list on following page. 04/15 Page 49 August 3, 2015 7033-277N...
  • Page 50 3100 Wood Stove Series (ACC) 31M-ACC-LE Service Parts Beginning Manufacturing Date: Sept. 2014 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 51 Air Control Rod Guide 7033-210 14.8 Latch, Magnet 229-0631 14.9 Timer Arm Assembly 7033-034 14.10 Timer (Only) Replacement Assembly SRV480-1940 Pedestal Assembly SRV7033-072 Logo, Quadra-Fire Pkg of 10 7000-649/10 Panel Assembly, Side Right SRV7033-080 Tile Frame SRV7033-324 Page 51 August 3, 2015 7033-277N...
  • Page 52 3100 Wood Stove Series (ACC) 31M-ACC-LE Service Parts Beginning Manufacturing Date: Sept. 2014 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Stocked Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
  • Page 53 3100 Wood Stove Series (ACC) 31M-ACC-LE Service Parts Beginning Manufacturing Date: Sept. 2014 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 54: Warranty Policy

    3100 Wood Stove Series (ACC) D. Warranty Policy Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance...
  • Page 55 3100 Wood Stove Series (ACC) WARRANTY CONDITIONS: ‡ 7KLV ZDUUDQW\ RQO\ FRYHUV ++7 DSSOLDQFHV WKDW DUH SXUFKDVHG WKURXJK DQ ++7 DXWKRUL]HG GHDOHU RU GLVWULEXWRU $ OLVW RI ++7 DXWKRUL]HG GHDOHUV LV DYDLODEOH RQ WKH ++7 EUDQGHG ZHEVLWHV ‡ 7KLV ZDUUDQW\ LV RQO\ YDOLG ZKLOH WKH ++7 DSSOLDQFH UHPDLQV DW WKH VLWH RI RULJLQDO LQVWDOODWLRQ ‡...
  • Page 56: Contact Information

    Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer, log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL •...

This manual is also suitable for:

Limited edition 31m-acc-leStep top uni-body 31st-acc