A. Design, Installation & Location Consider ations
Consideration must be given to:
Safety
Convenience
Traffi c fl ow
Chimney and chimney connector required
It is a good idea to plan your installation on paper, using exact
measurements for clearances and fl oor protection, before
actually beginning the installation. If you are not using an
existing chimney, place the appliance where there will be a
clear passage for a factory-built listed chimney through the
ceiling and roof.
We recommend that a qualifi ed building inspector and your
insurance company representative review your plans before
and after installation
If this appliance is in an area where children may be near it
is recommended that you purchase a decorative barrier to go
in front of the appliance. Remember to always keep children
away while it is operating and do not let anyone operate
this appliance unless they are familiar with these operating
instructions.
Service / Maintenance Tip:
In order to replace the tube channel a clearance of 19
inches (483mm) is required on the right side of stove in
order to remove the tubes with the stove in place. If space
is not available, the stove will have to be disconnected from
the chimney to proceed with the tube replacement. See
page 35.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult insurance carrier, local building, fi re offi cials or
authorities having jurisdiction about restrictions, installation
inspection, and permits.
WARNING
Asphyxiation Risk.
• Do NOT connect this unit to a chimney fl ue
servicing another appliance.
• Do NOT connect to any air distribution duct or
system.
May allow fl ue gases to enter the house.
March 2, 2007
B. Fire Safety
To provide reasonable fi re safety, the following should be
given serious consideration:
1.
Install at least one smoke detector on each fl oor of
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer's placement and installation instructions,
and be sure to maintain regularly.
2.
A conveniently located Class A fire extinguisher
to contend with small fires resulting from burning
embers.
3.
A practiced evacuation plan, consisting of at least two
escape routes.
4.
A plan to deal with a chimney fi re as follows:
In the event of a chimney fi re:
a.
Notify fi re department
b.
Prepare occupants for immediate evacuation.
c.
Close all openings into the stove.
d.
While awaiting fi re department, watch for ignition
of adjacent combustibles from overheated stove
pipe, hot embers or sparks from the chimney.
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
• Installation and use of any damaged appliance.
• Modifi cation of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
• Operating appliance without fully assembling all
components.
• Operating appliance without legs attached (if supplied with
unit).
• Do NOT Overfi re - If appliance or chimney connector glows,
you are overfi ring.
Any such action that may cause a fi re hazard.
Fire Risk.
Do not operate appliance before reading and
understanding operating instructions.
Failure to operate appliance properly may
cause a house fi re.