Travis Industries 864 HH Installation Manual page 63

Built-in direct vent fireplace
Hide thumbs Also See for 864 HH:
Table of Contents

Advertisement

Force the sheathed cable through
a
one of the locking flaps on the
junction box (repeat for the other
cable). Some force is needed.
The flap will lock the cable in place.
From
Blower Box
To Fireplace (36DV & 44 DV)
To Power Supply (864TRV)
OFF
Turn the dial all
the way counter-
clockwise until it
clicks off.
Attach the common (white) wires
b
together. Attach the ground
(exposed or green) wires together.
Then attach each of the hot (black)
wires from the cables to the two
wires on the rheostat (orientation
does not matter). Carefully pack
NOTE:Two junction
the wires into the junction box.
boxes are included -
use the best box for
your installation.
HIGH
The high position is
all the way counter-
clockwise, without
clicking off.
Phillips
Screwdriver
LOW
Turn the dial
all the way
clockwise.
Use a vacuum cleaner to remove
any debris from the power vent
blower.
Grill
Attach the cover plate
c
(either white or beige) with
the included screws. Slide
the knob (either white or
beige) over the rheostat
shaft.
Standard
Screwdriver

Advertisement