Approved Vent Configurations

If the diffuser is required to be in position # 2, you may wish to adjust the diffuser while the exhaust
restrictor is removed.
(closed) #6
# 5
# 4
# 3
# 2
(open - stock position) # 1
Loosen these four screws
on the exhaust restrictor.
Slide the restrictor to the correct
restrictor position (see the illustration
below). The rear screws indicate
restrictor position. In this example, the
restrictor is set in position # 3. Tighten
the screws to secure the restrictor.
NOTE: If using position 5 or 6 you will
need to remove the forward screws.
These screws are then re-inserted into
the back holes exposed while sliding
the restrictor.
Back of Firebox