ModBus Data Listing

ModBus Coil List
The following tables list the primary coils for the inverter interface to the network. The
table legend is given below.
• Coil Number - The network register address offset for the coil, in hex and decimal.
Actual network address is 30001 + offset. The coil data is a single bit (binary) value.
• Name - The functional name of the coil
• R/W - The read-only (R) or read-write (R/W) access permitted to the inverter data
• Description - The meaning of each of the states of the coils
Coil Number
hex
dec.
0000h 00000 (Reserved)
0001h 00001 Run command
0002h 00002 FW/REV command
0003h 00003 External trip (EXT)
0004h 00004 Trip reset (RS)
0005h 00005 (Reserved)
0006h 00006 (Reserved)
0007h 00007 Intelligent input terminal 1
0008h 00008 Intelligent input terminal 2
0009h 00009 Intelligent input terminal 3
000Ah 00010 Intelligent input terminal 4
000Bh 00011 Intelligent input terminal 5
000Ch 00012 Intelligent input terminal 6
000Dh 00013 (Not used)
000Eh 00014 Run/Stop status
000Fh 00015 FW/REV status
0010h 00016 Inverter ready
0011h 00017 (Reserved)
List of Coil Numbers
Name
R/W
R
R/W 0 .... Stop
R/W 0 .... REV
R/W 0 .... No trip event
R/W 0 .... No reset condition
R
R
R/W 0 .... OFF *1
R/W
R/W
R/W
R/W
R/W
R
R
R
R
SJ200
Inverter
2
Description
1 .... Run (enabled when A003=03)
1 .... FW (enabled when A003=03)
1 .... Trip occurred
1 .... Reset
1 .... ON
0 .... Stop (corresponds to D003
monitor)
1 .... Run
0 .... FW
1 .... RV
0 .... Not ready
1 .... Ready