2. Open the front cover by placing your fingers on the grooves on both sides of the cover as
shown below, and then pull the cover towards you.
Caution:
c
You must completely open the printer cover when replacing the developer cartridge;
otherwise, you may damage the printer.
3. Hold the photoconductor unit's casing by the handle and slowly pull it out of the printer.
Warning:
w
Do not touch the fuser, which is marked CAUTION Hot Surface. If the printer has been in
use, the fuser may be very hot.
Caution:
c
Be careful not to spill any remaining toner from the used developer cartridge. If toner is
spilled inside the printer, clean it with a clean, dry, lint-free cloth or with a
vacuum-cleaning device.
EPSON AcuLaser M1200 Series
Replacing Consumable Products
User's Guide