Dell Networking 7048 Release Note page 44

5.1.0.1 firmware release notes
Hide thumbs Also See for Networking 7048:
Table of Contents

Advertisement

Summary
"no enable authentication"
does not disable access to
privileged EXEC over the
telnet line
dot1q_api.c error during MIB
walk
sFlow Timeout settings for
CLI command
sFlow: Limit of 32 for the
number of interfaces for which
sFlow can be enabled
sFlow: Formatting errors with
some of the records
sFlow: The sample Pool field
is not being incremented
properly
sFlow: The sFlow agent field
isn't being filled in
Stack module inserted in Bay
1 and SFP+ module in Bay 2
CLI "switchport general
acceptable-frame-type"
different options than GUI
startup-config cannot be
restored via tftp
"show ip ospf database" does
not respect configuration of
"terminal length 0"
Occasionally, "clear config"
from console triggers
wio_api.c traceback
Radius config stops working
after reboot.
ISDP timers running fast.
VRRP hang
IPMC error messages and
forwarding issue.
Dynamic LAG Ports are
flapping/continuous trace
messages.
Simple Switch should have FC
enabled by default
42
User Impact
"no enable authentication" does not
disable access to privileged EXEC over
the telnet line
If LAG port is configured as general trunk
then log message is getting printed when
snmpwalk is accessing the MIB OID
agentLagSummaryAccessVlanID.
sFlow receiver timeout value should be
optional
Current limit of 32 for the number of
interfaces for which sFlow can be enabled.
Some of the sFlow records had formatting
errors.
Sample pool field will not be incremented
in the sFlow packet sent to the collector.
The sFlow agent field isn't being filled into
sFlow Packet.
With the presence of stack module at bay1,
SFP+ module in bay2 will not get detected
until the stack-module at bay1 is removed.
The CLI "switchport general acceptable-
frame-type" contains different options than
GUI.
TFTP script download or saved script
validation will leave the DUT in an
unusable state.
The CLI handler of the "show ip ospf
database" command does not consider the
terminal length configuration.
Occasionally, "clear config" from console
triggers wio_api.c traceback
Radius config stops working after reboot,
needs to be removed and re-added in order
to work again.
ISDP entries are timing out and dropping
off the list before the next update comes
in.
VRRP loss of mastership causes the switch
to hang.
Error messages indicating that IPMC table
are not set correctly in hardware.
Lags do not stay up on combo ports.
Enable Flowcontrol on simple mode.
Resolution
Corrected error in
authentication processing.
Corrected VLAN access
error.
Changed receiver timeout
value to be optional.
Changed the limit to allow
all sFlow instances.
Corrected sFlow header
problems.
Corrected sample pool field
error.
Corrected problem adding
sFlow agent address.
Corrected error that
prevented the detecting of
SFP+ module in bay 2.
Options are now the same.
Corrected script validation
problem.
Corrected terminal length
configuration handling.
Corrected "clear config"
internal message error.
Corrected error in Radius
user authentication
processing.
Corrected an error in the
ISDP timer disable
processing.
Corrected an error in the
VRRP processing of the
new IP address.
Corrected error message
processing which generated
false error messages.
Corrected an error in
mapping the physical ports
to a LACP logical port.
Flowcontrol enabled on
simple mode.
System Firmware Version 5.1.0.1
Affected
Platforms
All Platforms
All Platforms
All Platforms
All Platforms
All Platforms
All Platforms
All Platforms
PCM6220
All Platforms
All Platforms
All Platforms
All Platforms
All Platforms
All Platforms
All Platforms
All Platforms
All Platforms
All Platforms

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents