b. Press
button on the transmitter to set proper "Start Timer". The chirp & LED
pause will confirm entry. (Increase "Start Timer " is necessary.)
c.
Repeat steps 1 – 4.
Timer Checking Type
1. Turn the Ignition 'switch 'ON/OFF' 3 TIMES and stay in OFF position.
2. Push the Valet switch 11 times and hold it on the 11
long chirp is hearing then release the valet switch.
3. Press the transmitter
Checking Type". [3] LED flashes , [3] chirps to confirm this setting
Once you complete step 3, you can adjust and test "Start Timer" as below:
START TIMER PROGRAMMING: (TEST and ADJUST)
While the system is in Start Feature "E" programming mode,
1. Press the
button once on the transmitter to start the vehicle.
2. If everything goes well:
a. Press the '
button once on the transmitter to stop engine running. You have
been completed this programming successfully.
b.
Press
button on the transmitter to exit the program mode. There will be 3 long
chirps & 3 parking light flashes for confirmation.
3. If the crank time is too long, (Engine already successfully running, but still cranks):
a. Press the
button once on the transmitter to stop engine running.
b. Press the
button on the transmitter to set proper "Start Timer". The chirp & LED
pause will confirm entry. (Decrease "Start Timer" is necessary.)
c. Repeat the step1 – 4.
4. If the crank time is too short, (Engine not running, crank stopped before starting):
a. Press the
button once on the transmitter to stop engine running.
b. Press
button on the transmitter to set proper "Start Timer". The chirp & LED
pause will confirm entry. (Increase "Start Timer " is necessary.)
c.
Repeat the step1 – 4.

TEST MODE

In this test mode, this system can test the Zone 2 (Instant ground trigger), the Zone 3
(Door trigger), and the Zone 1 & Zone 4 (2 stage shock sensor) sensitivity. The
installer can save time to test the 2-stage shock sensor sensitivity and sensor without
using the traditional arming/disarming procedures to test the sensors.
Enter:
1. Turn the Ignition 'switch 'ON/OFF' 3 TIMES and stay in OFF position.
2. Push the Valet switch 11 times (holding in on the 11
chirp is heard then release the valet switch. You are now in the Start feature '"E"
programming mode.
a. Test the Zone 2 / Instant Ground Trigger & Zone 3 / Door Trigger:
Press and release the transmitter
LED flash, [1] siren/horn chirp to indicate your are in Zone 2 / instant ground
trigger and Zone 3 / Door trigger test mode.
Zone 2 / Instant Ground trigger (H6/17 Blue wire)
Zone 3 / Door trigger (H6/15 Green or H6/19 Violet wire)