H4. 3 Pin Door Lock Connector (Maximum 500 Ma Output); Negative Trigger Door Lock System - Autopage C3-RS1100 OLED Installation Manual

Professional 2-way 915 mhz. oled remote car starter & 6 channel alarm system with built-in temperature sensor and two way serial port data link
Table of Contents

Advertisement

The WHITE/BLACK wire provides an
instant shutdown for the remote start,
whenever it is grounded. Connect the
wire to the hood pin switch previously
installed. This wire must be routed
though a grommet in the firewall and
connected to the hood pin switch. If
the pin switch is to be used with an
alarm system, connect this wire with
diode.
Important! This connection is a safety wire and must be connected as shown and
tested as specifiled. Failure to do so may result in personal injury or propert y damage.
See detail of wiring in the following diagram. This wire may also be used if the vehicle
brake light circuit switches ground to the brake lights. An isolation diode must be
used for ground switched brake light circuits and must be connected to the output of
the brake switch.
H6/21 Orange wire – (-) 200mA Grounded Output When Armed –
This wire will become grounded when the alarm is armed. The current capacity of
this wire is 200mA. This output can control starter disable, when an intrusion is
detected and the system is triggered. The vehicles prevent from any unauthorized
starting.
H10/20: ORANGE wire
White wire
from control module
H1/1 VIOLET wire (Starter output)
form Heavy Gauge wire harne ss
H6/22 Black / Red Wire– (-) 200mA Timer Control Channel 5
(See Alarm Feature C – 6 Programming) This wire is built-in user -programmable timer output
provides a ground through this wire. Press the transmitter
You may program the built-in timer to send a ground signal for any time interval between 1
second and 2 minutes. For instance, this timer output may be used to turn on the headlight with
the remote control. Also on certain BMW, Mercedes Benz, Jaguar and Volkswagen cars, you
can use this unique timed output to allow remote closure of all power window and sunroof
w ithout the need for an external module!
H4. 3 PIN DOOR LOCK CONNECTOR: (Maximum 500mA Output)
( - ) Unlock Pulse
Blue Wire
(+) Lock Pulse
Red(not used)
( - ) Lock Pulse
Green Wire
( + ) Unlock Pulse
C3 RS1100REV. A
To: White/Black Wire /
Negative safety
Diode
IN4003 Diode
Purple wire
87
86
85
Red wire to
Ignition Switch
87a
30
"On"
"Off"
"Acc"
"Start"
Yello wire
and

NEGATIVE TRIGGER DOOR LOCK SYSTEM

Blue Wire Door Unlock
Red (not used)
Green Wire Door Lock
To Exiting
Door Lock Relay
16
Hood Pin Switch
To: Alarm instant
trigger Blue wire
Diode
Starter
Cut
X
buttons at the same time.
Locking
Master
Switch

Hide quick links:

Advertisement

Table of Contents
loading