Mitsubishi Electric Melservo-J2-SUPER series Instruction Manual page 139

General-purpose ac servo
Hide thumbs Also See for Melservo-J2-SUPER series:
Table of Contents

Advertisement

5. PARAMETERS
Class No. Symbol
Feeding function selection
1
*FTY
Used to set the feed length multiplication factor and manual pulse generator
multiplication factor.
Name and Function
ST1 coordinate system selection
(Refer to Section 4.2.2 to 4.2.4)
0: Address is incremented in CCW direction
1: Address is incremented in CW direction
When "1" is set, pressing the start switch for test
operation starts rotation in the reverse direction.
Feed length multiplication factor (STM)
(Refer to Section 4.2.3)
0: 1 time
1: 10 times
2: 100 times
3: 1000 times
Manual pulse generator multiplication factor
(Refer to Section 4.3.2)
0: 1 time
1: 10 times
2: 100 times
Servo-on (SON) -off, forced stop (EMG) -off
follow-up for absolute value command
in incremental system or absolute value command/
incremental value command specifying system
0: Invalid
1: Valid
Normally, when this servo amplifier is used
in the absolute value command method of the
incremental system, placing it in a servo off or
forced stop status will erase the home position.
When "1" is set in this parameter, the home
position will not be erased if the servo amplifier
is placed in a servo off or forced stop status.
Operation can be resumed when servo-on (SON)
is turned on again or forced stop (EMG) is canceled.
5 - 6
Initial
Setting
Unit
value
range
0000
Refer to
Name
and
function
column.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents