1) Turn the unit off and allow it to cool down to room temperature.
2) Turn off the gas supply to the insert.
3) Open the bottom louver.
4) Remove the door frame by lifting out from the bottom and lift up off
the glass door.
5) Remove the glass door.
a) Remove the 2 hooks shown below at the bottom of the glass
.
door
b) Swing the door out 45
o
from the bottom and lift up and
out.
6) Remove the burner by undoing the 2 screws shown. Carefully slide
the burner to the left. Then lift the burner up and out ensuring not to
spill glass crystals.
7) Carefully set aside the burner and glass crystals.
U32SE-5 FPI Direct Vent Gas Insert

VALVE ASSEMBLY REPLACEMENT

Glass Door
Door Frame
Burner
8) Remove the base cover by lifting up from the back and maneover
out.
9) Disconnect the EV1, EV2, and ground wires from the valve - as
shown below.
Ground
EV2
MAINTENANCE
Base Cover
EV1