Safety Label; Copy Of Safety Decal - Regency Sunrise U32SE-NG5 Owners & Installation Manual

U32se sunrise gas insert
Table of Contents

Advertisement

This is a copy of the label that accompanies each U32SE-5 Gas Insert.
We have printed a copy of the contents here for your review. The safety
label is located on a plate inside the base of the unit visible when the
bottom louver is opened.
NATURAL GAS FIREPLACE INSERT:
PROPANE GAS FIREPLACE INSERT:
Mantel Clearances
Max. Mantel depth
Max. Mantel height
Min. Mantel depth
Min. Mantel height
Floor to top of unit
* No Hearth required
FPI Fireplace Products International Ltd.,
Delta BC, CANADA
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and
Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA
501A, Manufactured Home Installations Standard
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner's manual for details.
This appliance is not convertible for use with other gases unless a certified kit is used.
WARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original
parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel
Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part
3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA
501A, Manufactured Home Installations Standard
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si un kit certifié est utilisé.
AVERTISSEMENT : Ce foyer a été converti pour utilisation avec un foyer au gaz encastrable et ne peut être utiliser pour brûler du bois ou d'autres
combustibles solides à moins que toutes les pièces d'origine aient été remplacées et que le foyer ait été approuvé de nouveau par l'autorité compétente.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS. /
GAZ À ÉVACUATION -
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas appliance is installed.
U32SE-5 FPI Direct Vent Gas Insert
Listed:
VENTED GAS FIREPLACE HEATER
/ FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour:
é
CANADA and U.S.A.
Tested to:
CAN/CGA-2.17-M91, ANSI Z21.88-2009 / CSA 2.33-2009
WN# 16516
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
5"
Low Setting Man. pressure
1.6"
Max. Manifold pressure
3.5"
Orifice size
#42
Minimum input
16,500
Maximum input
24,500
Factory Equipped For Altitude 0-4500ft. (0-1370m)
Min. supply pressure
11"
Low Setting Man. pressure
6.4"
Max. Manifold pressure
10"
Orifice size
#54
Minimum input
17,000
Maximum input
20,500
M
12"
(305mm)
N
17"
(432mm)
O
3-1/2"
(89mm)
P
13"
(330mm)
Q
20"
(508mm)
O
P
Q
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
Regency
NOTE:
label on the unit and if there is a difference, the label on the unit is
the correct one.
NE PAS ENLEVER CETTE ETIQUETTE
Serial No. / No de serie
MODEL U32SE-NG5
É
QUIP A L'UISINE POUR GAZ NATURAL
É
WC
(1.25 kpa)
Pression d'allimentation minimum
WC
(0.41 kpa)
Pression la tubulure d' chappement basse
WC
(0.87 kpa)
Pression la tubulure d' chappement lev e
DMS
Dimensions de l'orifice
Btu/h
(4.84
kW
)
D bit Calorifique minimum
é
Btu/h
(7.18 kW)
D bit Calorifique maximum
é
MODEL U32SE-LP5
É
QUIP A L'UISINE POUR GAZ PROPANE
É
WC
(2.73 kpa)
Pression d'allimentation minimum
WC
(1.59 kpa)
Pression la tubulure d' chappement basse
WC
(2.48 kpa)
Pression la tubulure d' chappement lev e
DMS
Dimensions de l'orifice
Btu/h (4.98 kW)
D bit Calorifique minimum
é
Btu/h (6.01 kW)
D bit Calorifique maximum
é
Minimum Clearances to Combustibles
from Insert
Side wall
A
10"
Ceiling
B
47-1/2" (1205mm)
M
Alcove Width
K
48"
N
L
Max. Alcove Depth
L
36"
MADE IN CANADA /FABRIQUE AU CANADA
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil

SAFETY LABEL

® units are constantly being improved. Check the
DO NOT REMOVE THIS LABEL /
356
é
à
é
é
é
à
é
à
é
é
é
à
B
(255mm)
L
(1220mm)
A
(915mm)
K
FOYER AU
918-845
5