Wiring Diagrams - Regency Sunrise U32SE-NG5 Owners & Installation Manual

U32se sunrise gas insert
Table of Contents

Advertisement

INSTALLATION
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat
will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
IMPORTANT:
If the optional remote control is used, the AA batteries normally installed into the battery holder must be removed. The AA batteries in the
receiver now operate the unit. Having AA batteries in both the battery holder and receiver will damage the gas valve.
16

WIRING DIAGRAMS

SureFire™ Switch
Standard Main On/Off Switch
or Optional Wall Switch
Proflame System
Configuration
886 GTMF
Wire Diagram
SureFire™ Switch
0.886.001
Proflame Valve
Note: 4 AA batteries must be installed to
operate the burner switch.
Do not use a 9 volt battery.
U32SE-5 FPI Direct Vent Gas Insert