OPTIONAL WALL THERMOSTAT

A wall thermostat may be installed if desired, follow the wiring diagram
below. FPI offers an optional programmable thermostat but any 250-750
millivolt rated non-anticipator type thermostat that is CSA, ULC or UL
approved may be used.
CAUTION
Do not connect the millivolt wall thermostat wires
to the 120V wires.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes:
1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label) at 15 minutes.
2) If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow the unit to burn for 15 min. to stabilize.
3) Check for proper draft.
Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the
responsibility of the manufacturer.
1) 4 AA batteries must be installed in the battery pack to operate the burner switch.
2) Install 2 AA batteries per side and connect as shown below.
OPTIONAL PEBBLES / GLASS CRYSTAL INSTALLATION
FOR FIREBOX BASE (AROUND BURNER)
Firebox (Around Burner) Packages
Unit
Glass Crystals
HZ54E / HZ54EPV
6 lbs
HZ42 / HZ42E / HZ40E
5 lbs
HZ42ST / HZ42STE / HZ42STEPV 5 lbs
HZ30E
2 lbs
HZI540EB
4 lbs
HZI390E/ HZI390EB
3 lbs
HZI234E
2 lbs
HZO42 / HZO42 (AUS)
3 lbs
P33S / P33SE
3 lbs
U32SE-5 FPI Direct Vent Gas Insert
Max. Length
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.

FINAL CHECK

BATTERY INSTALLATION

Pebbles
2 packages (6 x bags pebbles)
2 packages (6 x bags pebbles)
2 package (6 x bags pebbles)
1 package (3 x bags pebbles)
1.5 packages (4 x bags pebbles)
1 package (3 x bags pebbles)
1 package (3 x bags pebbles)
1 package (3 x bags pebbles)
1 package (3 x bags pebbles)

OPTIONAL REMOTE CONTROL

Use the FPI Remote Control Kit approved for this unit. Use of other
systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver
and a wall mounting plate.
1) Choose a convenient location on the wall to install the receiver and
the receptacle box (protection from extreme heat is very important).
Run wires from the fi replace to that location. Use Thermostat Wire
Table.
2) Connect the two wires to the gas valve. See wiring diagrams. Optional
wall switch GT/GTM using wire 0.584.907
3) Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline bat-
teries in the receiver. Install the receiver and its cover in the wall.
Switch the remote receiver to "remote" mode. The remote control is
now ready for operation.
CAUTION
INSTALLATION
CAUTION
Do not connect the millivolt
remote control
the 120V wires.
15