INSTALLATION
MINIMUM CLEARANCES TO COMBUSTIBLES
From Unit
Side Walls
A* 8" (203 mm)
Ceiling
B 47" (1194 mm)
Min. Mantel Height C 15" (381 mm)
Max. Mantel Depth
D 3-1/2" (89 mm)
Alcove Width
E 76" (1930 mm)
Alcove Depth
F
36" (914 mm)
* Alcove side wall must have a min. of 8" clearance
on one side.
COMBUSTIBLE MANTEL CLEARANCES
10
Due to the extreme heat this fi replace emits, the mantel clearances
are critical.
Note: A non-combustible mantel may be installed at a lower height
if the framing is made of metal studs covered with a non-
combustible board.
Mantel can be installed anywhere in shaded area or higher using the
above scale.
Note: Ensure the paint that is used on the mantel and the facing
is "heat resistant" or the paint may discolour.
®
Regency
E33S-1 Sunrise Gas Insert