MAINTENANCE
REMOVING VALVE
1) Shut off the gas supply.
2) Remove the louvers (and bay door if installed.)
3) Open the fl ush door and remove the door.
4) Remove the logs.
5) Remove the burner/grate assembly by removing the two screws
and then lift the burner assembly out.
Diagram 1: Remove the left and right screws and then lift out the
burner/grate assembly.
6) Remove the rear log stand by removing the 2 screws.
7) Disconnect the inlet gas line.
8) Disconnect the EV1, EV2, and ground wires from the valve - as
shown below.
58
Ground
EV1
EV2
9) Remove the 10 screws securing the valve tray assembly in place
(diagram 2) and then lift the entire assembly out (diagram 3).
screws
Diagram 2: Rear Log Stand & Valve Tray Assembly
10) Remove valve tray assembly.
Diagram 3: Lift out Valve Tray Assembly
INSTALLING VALVE
1) Install new valve assembly.
2) Reverse steps 9-1.
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace
Rear Log Stand