Regency P33E-NG4 Owners & Installation Manual page 42

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
11) Install 4 - AA batteries into the receiver.
12) Plug 'motor' wires into the back of the receiver and bundle wires
with the wire clip - as shown below.
13) Reattach wires from step 5.
42
14) Reinstall the DFC box onto the velcro pad on the fl oor of the unit.
15) Install the heat shield to the receiver with two screws and attach
to the fl oor of the unit with a velcro pad.
16) From the wire harness, plug the FCM wire into the fan control
module.
Fan Control Module
17) Install the heat shield onto the fan control module - then install
onto the velcro pad located on the fl oor of the unit located left
of the receiver.
18) Plug fan control module into recepticle located on the left hand
side of the unit.
19) Match the remote control to the receiver - see remote control
instructions.
20) Reverse steps 2 and 1.
21) Check to ensure there are no gas leaks..