Conversion From Ng To Lp - Regency P33E-NG4 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one LPG
Conversion Kit
LPG Conversion Kit Contains:
Qty. Part #
Description
1
904-163
Burner Orifi ce #54
1
918-590
Decal "Converted to
LPG"
1
908-528
Red "LPG" label
1
904-529
5/32" Allen Key
1
910-101
LPG Injector
(Pilot Orifi ce)
1
911-009
Hi/Lo Conversion LP
1
918-856
Instruction Sheet
Installation of the LPG
Conversion Kit:
1) Shut off the gas supply.
2)
a) Remove the louvers, bay door or
faceplate if installed.
b) Remove the logs, embers, and brick
panels (if installed).
3)
Remove the glass door.
a) Release the two hooks from the
bottom of the glass door.
b) Swing the door out 45 degrees from
the bottom - then lift up and out.
34

CONVERSION FROM NG TO LP

For P33E-4 Using SIT 886 NOVA Gas Valve
For the U32SE only:
3)
Remove the burner by undoing the 2
screws as shown below.
Burner
4) After screws have been removed,
slide the burner to the left, then lift out
carefully.
5)
Remove the base cover by lifting up
from the back, then maneuver it out.
Base Cover
Lift up from the back.
6)
Remove burner orifi ce with a 1/2" wrench
and discard. Use another wrench to hold
onto the elbow behind the orifi ce.
Burner Orifi ce
7)
Install the new LP burner orifi ce stamped
#54 and tighten.
8)
Remove the pilot shield by removing the
2 screws as shown below.
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace