1) Shut off the gas supply and disconnect all power to the unit.
2) Remove the louvers, bay door or faceplate, if installed.
3) Disconnect battery pack - located on the fl oor of the unit, as shown
below and discard.
4) Identify wires in the GTM/GTMF remote wiring harness.
(see wiring diagram.)
5) Remove DFC (digital fi rebox control box) from the fl oor of the unit.
6) Disconnect wire harness, ground wire and spark wire from DFC.
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace

GTMF REMOTE INSTALLATION

DFC
7) Connect the TPTH and TH wires - green to green and white to
white as shown below.
TPTH
TH
8) Plug in receiver DC supply wire - as shown below.
9) Remove the hi/lo knob by removing 2 screws as shown below.
10) Install the stepper motor in the same location the hi/lo knob was
removed from - with 2 screws as shown below.
INSTALLATION