Clearances W\ Bay Or Flush Front; Clearances With Contemporary Faceplate - Regency P33E-NG4 Owners & Installation Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
The clearances listed below are Minimum
distances unless otherwise stated:
A major cause of chimney related fi res is
failure to maintain
required clearances (air space) to combus-
tible materials.
It is of the greatest importance that this
fi replace and vent system
be installed only in accordance with these
instructions.
Clearance to Combustibles from:
Back
0"
Side
0"
Floor
0"
NOTE: The minimum fl oor clearance must be
maintained
from the top surface of the carpeting, tile,
etc.

CLEARANCES WITH CONTEMPORARY FACEPLATE

The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this fi replace and vent system be installed only in accordance with these instructions.
Caution Requirements
The top, back and sides of the fi replace are defi ned by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
*Note: All measurements are from the top/side of the unit, not optional front.
Clearance:
A: *Front Floor Clearance (min.)
B: *Sidewall
C: *Ceiling
(room and/or alcove)
D: Alcove Width
E: Alcove Depth
10
CLEARANCES WITH BAY OR FLUSH FRONT
Minimum Clearance from Top of Unit to:
Mantel*
Ceiling
from top of unit.
Side Wall Clearance
Bay or Flush Front
Minimum Vent Clearances:
2-1/2" (64mm) Horizontal Top
1-1/2" (38mm) Horizontal Side
1-1/2" (38mm) Horizontal Bottom
1-1/4" (32mm) Vertical Vent Clearance
(Rigid Vent)
(0mm)
1-1/2" (38mm) Vertical Vent Clearance
(0mm)
(Flex Vent)
(0mm)
Alcove Clearances:
Max. Depth
Min. Width
Min. Height
* see mantel clearance instructions.
Dimension
1" (25mm)
7-1/2" (241mm)
30" (889mm)
48" (1219mm)
36" (914mm)
min. 7" (177mm)
30"
(762mm)
7-1/2" (191mm)
36"
(914mm)
48"
(1219mm)
59"
(1499mm)
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fi replace and vent
system be installed only in accordance with these instructions.
C
Measured From:
Underside of Unit
Side of Unit
Top of Unit
Sidewall to Sidewall (Minimum)
Front to Back Wall (Maximum)
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace
Clearances for Bay or Flush Front
Warning
Fire hazard is an extreme risk if these
clearances are not adhered to.
WARNING
B
Close to Ceiling
Flue Clearances to
Combustibles
Horizontal - Top
2-1/2"
Horizontal - Side
1-1/2"
Horizontal - Bottom
1-1/2"
Vertical (Flex Vent)
1-1/2"
Vertical (Rigid)
1-1/4"