Table 2.8 Frame Sync Hi-Z Connector
Item
Connector type
Connector
designation
Pin:
Impedance
2.7.7

Ethernet

The equipment has an Ethernet remote control port for SNMP
Control. This is also used for high speed data over Ethernet
output and engineering debug purposes.
Table 2.9 Ethernet Pin-outs
Item
Connector type
Connector
designation
Pin-outs
(Unused pins not
connected)
2.7.8

ASI IN

A BNC socket is provided for detection of the transport
stream lock on the ASI input.
Table 2.10 Digital Input Connector
Item
Connector type
Connector
designation
Pin-outs
2-14
Specification
BNC 75 Ω socket
FRAME SYNC
Centre
Analogue Black and Burst Input
Shield
Ground/Chassis
Last unit must be terminated with 75 Ω
Specification
RJ-45 (100BaseT)
10/100BaseT
Pin 1 - Tx Out (+)
Pin 2 - Tx Out (-)
Pin 3 - Rx In (+)
Pin 6 - Rx In (-)
Specification
BNC 75 Ω female socket
ASI IN
Centre
ASI Input
Shield
Ground/Chassis
8
1
10/100BaseT
ASI IN
EN/LZT 790 0003/2 R1A