Ventilation; Openings In The Covers; Care In Positioning; Protection From Moisture - Ericsson RX1290 Reference Manual

Multi-format receiver software version 3.0.0 (and later)
Table of Contents

Advertisement

2.3.2

Ventilation

2.3.3

Openings in the Covers

Side openings in the unit, as well as side-mounted cooling fans, are provided for
ventilation. They ensure reliable operation of the product and protect it from
overheating. The openings of the fans must not be blocked or covered.
Fans are mounted on
this side of the unit
Figure 2.1 Air-flow Through the Equipment
2.3.3.1

Care in Positioning

The fans contained within this unit are not fitted with a dust/insect filter. Pay
attention to the environment in which it is to be used.
Do not install equipment so that the air intake of one aligns with the outlet on
another. Provide baffles and adequate spacing.
The equipment should never be placed near or over a radiator or other source of heat.
It should not be placed in a built-in installation such as a rack unless proper ventilation
is provided and the instructions have been adhered to.
Allow at least 40 mm free air-space at each side of the equipment to ensure
adequate cooling. Racks containing stacked equipment may need to be forced air-
cooled to reduce the ambient temperature within the rack.
2.3.3.2

Protection from Moisture

Do not install this equipment in areas of high humidity or where there is a danger of
water ingress.
EN/LZT 790 0003/2 R1A
Cautions!
Installing the Equipment
Air is released through
vents at this
side of the unit.
2-5