Sanyo PLC-WTC500AL - 5000 Lumens Manual
Sanyo PLC-WTC500AL - 5000 Lumens Manual

Sanyo PLC-WTC500AL - 5000 Lumens Manual

Rs232c basic basic serial command functional specifications
Hide thumbs Also See for PLC-WTC500AL - 5000 Lumens:
Table of Contents

Advertisement

Quick Links

BASIC SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-WTC500L
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Business Division

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-WTC500AL - 5000 Lumens

  • Page 1 BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-WTC500L Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Business Division...
  • Page 2: Table Of Contents

    PLC-WTC500L Basic Serial Command Functional Specifications Contents 1. Overview ..........................4 2. Serial Interface Specification ...................4 2.1. Transfer Specification ....................4 2.2. Connection ........................4 3. Notes for Communication ....................5 4. Functional Execution Command Table ................6 5. Status Read Command Table ...................7 6. Functional Execution Command ..................8 Format ........................8 When the command pipelining is needed ............8 Transfer Example ....................8...
  • Page 3 PLC-WTC500L Basic Serial Command Functional Specifications 6.32 POWER MANAGEMENT CANCEL Command ........... 14 6.33 POWER MANAGEMENT SHUTDOWN Command ..........14 6.34 D.ZOOM + Command ................... 14 6.35 D.ZOOM - Command .................... 15 6.36 INPUT 3 VIDEO Command .................. 15 6.37 INPUT 3 S-VIDEO Command ................15 6.38 POINTER RIGHT Command ................
  • Page 4: Overview

    PLC-WTC500L Basic Serial Command Functional Specifications 1. Overview 0û These specifications define projector control commands for PLC-WTC500L. 0û The projector control commands are used to control a projector through RS-232C from a computer. 2. Serial Interface Specification 2.1. Transfer Specification Item S p e c i f i c a t i o n Synchronous system...
  • Page 5: Notes For Communication

    PLC-WTC500L Basic Serial Command Functional Specifications 3. Notes for Communication 0û The projector command is defined as one command per line that starts with “C” and ends with carriage return (0x0D). 0û When carriage return (0x0D) is received, decoding starts. 0û...
  • Page 6: Functional Execution Command Table

    PLC-WTC500L Basic Serial Command Functional Specifications 4. Functional Execution Command Table Command Command Item Item POWER ON BRIGHTNESS + POWER OFF (QUICK POWER OFF) BRIGHTNESS - POWER OFF INPUT 2 VIDEO INPUT 2 Y,Pb/Cb,Pr/Cr INPUT 1 INPUT 2 RGB INPUT 2 INPUT 3 IMAGE NETWORK...
  • Page 7: Status Read Command Table

    PLC-WTC500L Basic Serial Command Functional Specifications Command Item Command Item FREEZE ON FREEZE OFF ZOOM - ZOOM + AUTO PC ADJ FOCUS - PRESENTATION TIMER FOCUS + KEYSTONE ! ‘ KEYSTONE ! “ INPUT1 HDMI KEYSTONE → INPUT 1 ANALOG RGB KEYSTONE ←...
  • Page 8: Functional Execution Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6. Functional Execution Command 6.1 Format 0û PC issues a command in the following format: “C” Command [CR] Command: two characters (See Functional Execution Command Table) 0û Projector decodes the received data and returns the result when getting ready to receive the next command.
  • Page 9: Operation Requirements

    PLC-WTC500L Basic Serial Command Functional Specifications 6.4 Operation Requirements In the following status of projector, Available Functional Execution Commands are limited. Projector Status Available Functional Execution Commands Standby Mode C00: POWER ON C00: POWER ON ! ’ Countdown is terminated C01: POWER OFF C02: POWER OFF ! ’...
  • Page 10: Power On Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6.5 POWER ON Command Command “C00” [CR] Power ON When already Power is ON, no operation is started. Detail When sending this command during Countdown in process, Countdown is terminated. Acceptable [ACK] [CR] Response Unacceptable “?”...
  • Page 11: Input 3 Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6.10 INPUT 3 Command Command “C07” [CR] Select Input 3. This command works differently from the command by “Input 3” Detail key of the remote control. When Input 3 has been selected, this command does not execute the source switching;...
  • Page 12: Video Mute On Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6.16 VIDEO MUTE ON Command Command “C0D” [CR] Video Mute ON Detail This command works the same way as “SHUTTER” button of the remote control for SHUTTER CLOSE, but does not work for SHUTTER OPEN Acceptable [ACK] [CR] Response...
  • Page 13: Display Clear Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6.22 DISPLAY CLEAR Command Command “C1E” [CR] Detail Clear On-screen Display under all conditions Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.23 BRIGHTNESS + Command Command “C20” [CR] Detail Increment Brightness by 1 according to user control. Acceptable [ACK] [CR] Response...
  • Page 14: On Start Set Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6.29 ON START SET Command Command “C28” [CR] Enable Power ON Start Detail This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.30 ON START CANCEL Command Command “C29”...
  • Page 15: D.zoom - Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6.35 D.ZOOM - Command Command “C31” [CR] Enter Digital Zoom mode and reduce image size Detail This command works the same as “D.ZOOM ” button of the remote control. Acceptable [ACK] [CR] Response Unacceptable “?”...
  • Page 16: Pointer Down Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6.41 POINTER DOWN Command Command “C3D” [CR] Move down the Pointer of On-Screen Display Menu Detail This command works the same way as “▼” button of the projector. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.42 ENTER Command Command “C3F”...
  • Page 17: Focus + Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6.47 FOCUS + Command Command “C4B” [CR] Adjust on-screen focus by making focal length longer. (The lens moves backward Detail This command works the same way as “FOCUS” button of the remote control. Acceptable [ACK] [CR] Response Unacceptable...
  • Page 18: Lens Shift Left Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6.54 LENS SHIFT LEFT Command Command “C5F” [CR] Detail Move projection area leftward. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.55 LENS SHIFT RIGHT Command Command “C60” [CR] Detail Move projection area rightward. Acceptable [ACK] [CR] Response Unacceptable...
  • Page 19: Keystone ! ' Command

    PLC-WTC500L Basic Serial Command Functional Specifications 6.60 KEYSTONE →Command Command “C90” [CR] Correct keystone distortion by reducing right part of image. This command Detail invokes both operations of keystone distortion correction and OSD display, regardless of whether the “KEYSTONE” OSD has been already displayed or not. Acceptable [ACK] [CR] Response...
  • Page 20: Status Read Command

    PLC-WTC500L Basic Serial Command Functional Specifications Status Read Command 7.1 Format 0û PC issues a command in the following format. “CR” Command [CR] Command: one character (See Status Read Command Table) 0û When projector receives an appropriate command, it returns the required data in string. Required Data [CR] Required Data: string (See Status Read Command Table) 0û...
  • Page 21 PLC-WTC500L Basic Serial Command Functional Specifications 0 Details for Response0 0û “00” [CR] Status: Power ON Normal image is on-screen. “80” [CR] 0û Status: Standby When the status is Standby, Status Read Commands are always accepted, but any Functional Execution Commands are not accepted except for POWER ON command. 0û...
  • Page 22 PLC-WTC500L Basic Serial Command Functional Specifications 0û “88” [CR] Status: Standby after Cooling Down due to Abnormal Temperature When the status becomes Standby after the temperature goes down by Cooling Down operation invoked due to Abnormal Temperature, the projector returns “88” [CR]. This indicates Abnormal Temperature caused turning to Standby status.
  • Page 23 PLC-WTC500L Basic Serial Command Functional Specifications 0û “2C” [CR] Status: Cooling Down in process due to Shutter management function This indicates it has moved to Cooling down status according to the setting of Shutter Management function in setting menu. During this time, Functional Execution Commands are not accepted.
  • Page 24: Input Mode Read Command

    PLC-WTC500L Basic Serial Command Functional Specifications 7.5 Input Mode Read Command Command “CR1” [CR] Detail Get currently selected Input No. Acceptable “%1” [CR] ”1” = Input 1 is selected. “2” = Input 2 is selected. Response “3” = Input 3 is selected. “4”...
  • Page 25: Temp Read Command

    PLC-WTC500L Basic Serial Command Functional Specifications 7.8 Temp Read Command Command “CR6” [CR] Get the information of temperature inside a projector. Detail With several built-in temperature sensors, it can get all the temperatures at once. Acceptable “%1 _ %2 _ %3” [CR] %1 = Temp.