PLC-WTC500L Expand Serial Command Functional Specifications
8.6.3 CF_INPUT 1 Command
Command
"CF_INPUT1_%1" [CR]
"HDMI" ----------------------------- Select HDMI Input
%1
"ANALOG" ------------------------ Select PC Analog Input
"SCART" --------------------------- Select SCART Input
Select Input 1 as well as Source specified in %1 (Available only in the normal
Details
Power ON status)
Acceptable
Response
Unacceptable
8.6.4 CF_INPUT 2 Command
Command
"CF_INPUT2_%1" [CR]
"VIDEO" ---------------------------- Select Composite Video Input
"YPBPR" --------------------------- Select Y,Pb/Cb,Pr/Cr Input
%1
"YCBCR" --------------------------- Select Y,Pb/Cb,Pr/Cr Input
"ANALOG" ------------------------- Select RGB Input
Select Input 2 as well as Source specified in %1. (Available only in the normal
Details
Power ON status)
Acceptable
Response
Unacceptable
8.6.5 CF_INPUT 3 Command
Command
"CF_INPUT3_%1" [CR]
"VIDEO" ---------------------------- Select Composite Video Input
%1
"S-VIDEO" ------------------------- Select S-Video Input
Select Input 3 as well as Source specified in %1.
Details
(Available only in the normal Power ON status)
Acceptable
Response
Unacceptable
8.6.6 CF_INPUT 4 Command
Command
"CF_INPUT4_%1" [CR]
%1
"NETWORK" ----------------------- Select input from PJ-Net
Select Input 4 as well as Source specified in %1. (Available only in the normal
Power ON status)
Details
*With PJ-Net unattached, this command is invalid and error code "103" is returned.
*With PJ-Net attached and the power OFF, error code "101" is returned.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
26/75