Removing The Power Supply Shield Plate; Removing The Fixing Film Unit - Canon MF3110 - ImageCLASS Laser Multifunction Service Manual

Mf3110 series
Hide thumbs Also See for MF3110 - ImageCLASS Laser Multifunction:
Table of Contents

Advertisement

Chapter 3
3.6.1.11 Removing the Power
Supply Shield Plate
1) Remove the 5 screws [1] to remove the power
supply shield plate [2].
[2]
[1]
[1]
F-3-255
3.6.1.12 Removing the Fixing
Film Unit
1) Remove the 2 screws [1] and take off the Fixing
cover [2].
[1]
[2]
F-3-256
3-64
2) Remove the 2 screws [1]. Remove the Fixing entrance
guide [2] by sliding it sideways back and forth.
0007-7748
F-3-257
3) Disengage the connector [1] of the power supply
board.
4) Remove the grounding springs and the pressure
springs [2] on both sides.
5) Remove the pressure plates [3] on both sides.
0007-7749
[2]
F-3-258
[1]
[2]
[3]
[1]
[2]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imageclass mf3111Laserbase mf3110

Table of Contents