2.8 Suppression bandwidths and setpoint limits

Function diagrams (see SINAMICS S List Manual)
● 1550 Setpoint channel
● 3040 Direction limitation and direction reversal
Overview of key parameters (see SINAMICS S List Manual)
Adjustable parameters
● p1110[CDS] BI: Inhibit negative direction
● p1111[CDS] BI: Inhibit positive direction
● p1113[CDS] BI: Direction reversal
Parameterization with STARTER
The "Speed setpoint" parameter screen is selected with the
STARTER commissioning tool:
2.8
Suppression bandwidths and setpoint limits
Description
In the range 0 U/min to setpoint speed, a drive train (e.g. motor, coupling, shaft, machine)
can have one or more points of resonance, which can result in vibrations. The suppression
bandwidths can be used to prevent operation in the resonance frequency range.
The limit frequencies can be set via p1080[DDS] and p1082[DDS]. These limits can be
changed during operation with the connectors p1085[CDS] and p1088[CDS].
58
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
icon in the toolbar of the
Drive Functions