Control Board Pc1 Testing Information (Use With Section 6-5) - Miller Electric SYNCROWAVE 250 Technical Manual

Arc welding power source
Table of Contents

Advertisement

6-4. Control Board PC1 Testing Information (Use With Section 6-5)

1
4
Test Equipment Needed:
TM-353 Page 30
2
5
3
Y Disable high frequency by
placing
High
Frequency
switch S2 in Off position
before testing unit.
Be sure plugs are secure before
testing. See Section 6-5 for specific
values during testing.
1
Control Board PC1
2
Receptacle RC51
3
Receptacle RC52
4
Receptacle RC53
5
Receptacle RC54
6
Receptacle RC55
6
SB-178 976-A / ST-800 344-A
Syncrowave 250

Hide quick links: