Remote 14 Receptacle; 115 Volts Ac Duplex Receptacle And Shielding Gas Connections - Miller Electric SYNCROWAVE 250 Technical Manual

Arc welding power source
Table of Contents

Advertisement

3-8. Remote 14 Receptacle

A
J
K
I
B
C L N
H
M
D
G
F
F
E
ST-154 795-C
*The remaining sockets are not used.

3-9. 115 Volts AC Duplex Receptacle And Shielding Gas Connections

TM-353 Page 10
Socket*
A
5
6
1
7
3
2
Socket Information
A
24 volts ac.
B
Contact closure to A completes 24 volts ac contactor control
circuit.
C
Command reference; 0 to +10 volts dc output to remote control.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from remote control.
K
Chassis common.
4
Y Turn
Off
power
before
connecting to receptacle.
1
115 V AC Receptacle
Receptacle is protected from over-
load by circuit breaker CB1 (see
Section 7-2).
2
Gas Valve In Fitting
3
Gas Valve Out Fitting
Fittings have 5/8-18 right-hand
threads
4
Cylinder Valve
Open valve slightly so gas flow
blows dirt from valve. Close valve.
5
Regulator/Flow Gauge
6
Flow Adjust
Typical flow rate is 20 cfh (cubic feet
per hour) (9.4 L/min)
7
High Frequency Control (see
Section 4-1)
Ref. ST-154 795-C / Ref. ST-157 858