Receptacle
Pin
RC55
1
2
3
4
5
6
7
8
9
10
TM-353 Page 32
Circuit common
+1.65 volts dc per 100 amperes of weld output with respect to pin 1
–15 volts dc output
0 to +4 volts dc input from min. to max. of Arc Control R2 with Arc Control switch S6 On
10 volts ac input for synchronization
+5.8 volts dc output
–15 volts dc input from Max. Penetration setting of AC Balance control R3 to +5.8 volts dc input at
Max. Cleaning setting of R3
0 to 80 volts dc voltage feedback signal (rectified arc voltage) with respect to pin 9
0 to 80 volts dc voltage feedback signal (rectified arc voltage) with respect to pin 8
0 to +4 volts dc input from min. to max. of Arc Control R2 with Arc Control switch S6 Off
Value