Print Quality Anomaly

5.3.2
This section describes how to isolate a print quality problem from the possible causes.
Possible Cause
Symptom
Poor development
Improper charging
Image transfer
problem
Paper problem
Defective optical
unit
Improper print
density setting
Foggy
background
Poor development
Improper charging
Improper print
density setting
Defective optical
unit
Rev. A
Table 5-15. Print Quality Anomaly
Part Name
Imaging
Imaging
cartridge
Image transfer surface of image
roller
Paper
Optical unit
Imaging
charge
Drum
Optical unit
Check Item
Check the toner level
in the imaging
cartridge.
Check to see if the
transfer roller is
damaged.
Check to see if PPer
is moist.
Check the wiring of
developing bias line.
Check the wiring of
PC drum charging
bias line.
Troubleshooting
Remedy
Shake the imaging
cartridge.
Replace the imaging
cartridge.
Replace the PWB-F
board.
Replace the imaging
cartridge.
Replace the PWB-F
board.
Replace the image
transfer roller.
Replace the PWB-F
board.
Replace the optical
unit.
Adjust the print density
Replace the imaging
cartridge.
Replace the PWB-F
board.
Replace the PWB-F
board.
Replace the imaging
cartridge.
Adjust the print density
Replace the optical
unit.