Disassembly and Assembly
High Voltage Supply Board (PWB-F) Removal
3.2.3.5
1. Remove the housing. (Refer to Section 3.2.l.l.)
2. Remove the rear frame. (Refer to Section 3.2.1.2.)
3. Disconnect connectors CN1 and CN2 on thehighvoltage supply board (PWB-F).
4. Remove 3 CPB screws (M3 x 8), and remove the high voltage supply board.
Figure 3-9. Removing the High Voltage Supply Board