When a new supply is installed into the printer, the count for that Customer Replaceable
Consumable, or CRC, is reset to zero. After the new CRC is installed, the printer blows the CRC
fuse. If a used consumable is installed, the printer detects the blown fuse. Because the fuse is
already blown, the CRC count will not be reset to zero for the used supply.
When installing a used CRC, use the hidden Reset menu to individually reset the count to zero.
Check CRC Status
In this exercise, you will check the status of the consumables.
1.
Consumable
Toner Cartridges: Black
Toner Cartridges: Magenta
Toner Cartridges: Cyan
Toner Cartridges: Yellow
Imaging Units: Black
Imaging Units: Magenta
Imaging Units: Cyan
Imaging Units: Yellow
Fuser
Transfer Unit
2.
PHASER 7300 CARE WORKSHEET
0
If the Front Panel has an error message indicating it is time to replace a
consumable, and a used consumable is installed, the error message will
remain on the display until the CRC count is reset.
Determine consumables status:
At the Front Panel, select Printable Pages Menu, then press OK.
Scroll to Print Supplies Page, then press OK. The Supplies Usage Page is generated.
Use the page to locate and record the following information:
Date Installed
Press the Back key to return to the main menu.
Locate and record the total print count:
Select Menus, then press OK.
Scroll to Supplies Info Menu, then press OK.
Scroll to Total Print Count, then press OK.
Record the value _________________________________.
Press the Back key to return to the main menu.
Pages/Life Remaining