PLV-WF20 Expand Serial Command Functional Specifications
7. Error Code Table
Error Code
000
101
102
103
201
301
302
303
402
-When the received data cannot be decoded
?
-Parameter designation error (wrong digit number,
including invalid value, etc.)
Normal reception (This is "Not" error)
Specified function is not available in the selected
mode
Specified value is out of range (Not reflected)
Command mismatched to Hardware (the command
is for Optional function which is not implemented)
Incremented or decremented value or values are
beyond upper or lower limits.
Not executable due to screen capturing in process.
Prompting reissue of the command after a while.
Not executable due to Auto set up in operation.
Prompting reissue of the command after a while.
Not executable due to memory card viewer in
process.
Prompting reissue of the command after a while.
Not executable due to PIN code in operation.
Prompting reissue of the command after a while.
Contents
16/68