Sanyo PLV-HD2000 - 7000 Lumens Manual
Sanyo PLV-HD2000 - 7000 Lumens Manual

Sanyo PLV-HD2000 - 7000 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLV-HD2000 - 7000 Lumens:

Advertisement

Quick Links

EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLV-HD2000
SANYO Electric Co., Ltd
Home Electronics Group
AV Company
Projector Business Unit

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLV-HD2000 - 7000 Lumens

  • Page 1 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLV-HD2000 SANYO Electric Co., Ltd Home Electronics Group AV Company Projector Business Unit...
  • Page 2: Table Of Contents

    PLV-HD2000 Expand Serial Command Functional Specifications CONTENTS 1. Overview ........................4 2. Serial Interface Specification ..................4 2.1. Communication Specification ................. 4 2.2. Connection ....................... 4 3. Note for communication ..................... 5 4. Name Definition ......................5 5. Functional Execution Command Table..............6 5.1.
  • Page 3 PLV-HD2000 Expand Serial Command Functional Specifications 9.5. Status Read Command for Video................38 9.6. Input Status Read Command ................39 9.7. Screen Status Read Command ................45 9.8. Lamp Status Read Command................46 9.9. Setting Status Read Command ................48 9.10.
  • Page 4: Overview

    PLV-HD2000 Expand Serial Command Functional Specifications 1. Overview ・ This Functional Specification defines communication functions to Network card for PLV-HD2000. ・ The Commands are designed to communicate with Network board, but most commands can be used to remote-control a projector through RS-232C from a computer. Therefore these commands are defined as Expand Serial Commands.
  • Page 5: Note For Communication

    PLV-HD2000 Expand Serial Command Functional Specifications Note for communication 3. ・ Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). ・ When a projector receives carriage return (0x0D), it starts decoding. ・...
  • Page 6: Functional Execution Command Table

    PLV-HD2000 Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1. Image Command Table Execute command Item Set value of Brightness CF_BRIGHT_%1 [CR] Set value of Contrast CF_CONT_%1 [CR] Set value of Color CF_COLOR_%1 [CR] Set value of Tint CF_TINT_%1 [CR] Set value of Sharpness CF_SHARP_%1 [CR]...
  • Page 7: Screen Command Table

    PLV-HD2000 Expand Serial Command Functional Specifications 5.4. Screen Command Table Execute command Item Select Screen size CF_SCREEN_%1 [CR] Set value of V Scale CF_VSCALE_%1 [CR] Set value of V Position CF_VPOS_%1 [CR] Set value of H Scale CF_HSCALE_%1 [CR] Set value of H Position CF_HPOS_%1 [CR] 5.5.
  • Page 8: Status Read Command Table

    PLV-HD2000 Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1. Image Status Read Command Table Status read command Item Get value of Brightness CR_BRIGHT [CR] Get value of Contrast CR_CONT [CR] Get value of Color CR_COLOR [CR] Get value of Tint CR_TINT [CR] Get value of Sharpness CR_SHARP [CR]...
  • Page 9: Input Status Read Command Table

    PLV-HD2000 Expand Serial Command Functional Specifications 6.4. Input Status Read Command Table Status read command Item Get selected Input No CR_INPUT [CR] Get selected Input Source CR_SOURCE [CR] Get selected source for Input 1 CR_SRCINP1 [CR] Get selected source for Input 2 CR_SRCINP2 [CR] Get selected source for Input 3 CR_SRCINP3 [CR]...
  • Page 10: Setting Status Read Command Table

    PLV-HD2000 Expand Serial Command Functional Specifications 6.7. Setting Status Read Command Table Status read command Item Get setting status of Blue Back CR_BBACK [CR] Get setting status of Display CR_DISP [CR] Get setting status of Logo CR_LOGO [CR] Get selected Remote Control Code CR_RCODE [CR] Get selected language CR_LANG [CR]...
  • Page 11: Functional Execution Command

    PLV-HD2000 Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1. Format PC issues a command in the format below: Pattern1: “CF _ Command” [CR] Pattern2: “CF _ Command _” %1 [CR] CF_: Header Command: String %1: Parameter (string) _: Space (To separate Command and Parameter) The projector decodes the received data and when it gets ready to receive the next command, it returns the response.
  • Page 12: Image Command

    PLV-HD2000 Expand Serial Command Functional Specifications 8.4. Image Command 8.4.1. CF_ BRIGHT Command Command “CF_BRIGHT_%1” [CR] “000-063” --------- Directly specify setting value of Brightness “UP” ---------------- Increment setting value of Brightness by 1 “DN” ---------------- Decrement setting value of Brightness by 1 Set Brightness value (valid only when it is in the normal Power ON status) The value set by this command is not stored in the projector’s memory.
  • Page 13 PLV-HD2000 Expand Serial Command Functional Specifications 8.4.5. CF_SHARP Command Command “CF_SHARP_%1” [CR] “000-015” --------- Directly specify setting value of Sharpness. “UP” ---------------- Increment setting value of Sharpness by 1. “DN” ---------------- Decrement setting value of Sharpness by 1. Set Sharpness value (valid only when it is in the normal Power ON status) The value set by this command is not stored in the projector’s memory.
  • Page 14 PLV-HD2000 Expand Serial Command Functional Specifications 8.4.8. CF_COLTEMP Command Command “CF_COLTEMP_%1” [CR] “000” ---------------- XLow “001” ---------------- Low “002” ---------------- Mid “003” ---------------- High Set level of Color Temp. (valid only when it is in the normal Power ON status) The value set by this command is not stored in the projector’s memory.
  • Page 15 PLV-HD2000 Expand Serial Command Functional Specifications 8.4.11. CF_IMAGE Command Command “CF_IMAGE_%1” [CR] “STANDPC” ------- Standard (PC) (Image Adj. value is fixed to factory default for Still Image) “STANDAV” -------- Standard (AV) (Image Adj. value is fixed to factory default for Moving Image) “REAL”...
  • Page 16 PLV-HD2000 Expand Serial Command Functional Specifications 8.4.13. CF_APCTRL Command Command “CF_APCTRL_%1” [CR] “L1” ------------------- Set Auto Picture Control to Level 1. “L2” ------------------- Set Auto Picture Control to Level 2. “OFF” ---------------- Set Auto Picture Control to OFF. Set the level of Auto Picture Control (valid only when it is in the normal Power ON Details status) Acceptable...
  • Page 17: Display Control Command

    PLV-HD2000 Expand Serial Command Functional Specifications 8.5. Display Control Command 8.5.1. CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000-0031” -------- Directly spcify setting value of Fine Sync “UP” ------------------ Increment setting value of Fine Sync by 1 “DN” ------------------ Decrement setting value of Fine Sync by 1 Set Fine Sync value (valid only when it is in the normal Power ON status) The value set by this command is not stored in projector’s memory.
  • Page 18 PLV-HD2000 Expand Serial Command Functional Specifications 8.5.4. CF_H-POS Command Command “CF_H-POS_%1” [CR] “0000 - nnnn” ---- Directly specify setting value of Horizontal Position “nnnn” indicates maximum value, which is current value of Input is (Total Dots - Display Dots). “UP” ---------------- Increment setting value of Horizontal Position by 1 “DN”...
  • Page 19 PLV-HD2000 Expand Serial Command Functional Specifications 8.5.6. CF_DLINE Command Command “CF_DLINE_%1” [CR] “0100 - nnnn” --- Directly specify setting value of Display Line “nnnn” indicates maximum value, which is current value of Input is (Total Line – Vertical Position). “UP” --------------- Increment setting value of Display Line by 1 “DN”...
  • Page 20 PLV-HD2000 Expand Serial Command Functional Specifications 8.5.8. CF_SETDISPADJ Command Command “CF_SETPCADJ_%1” [CR] “PAL” “SECAM” “XGA1” “1080I60 “MODE16” “EXT24” --------------- Etc. Apply the values set in Display adjust menu to the screen image. When %1 in Display adjust commands (following seven commands) is directly specified, they are not be applied to the screen image without this command.
  • Page 21 PLV-HD2000 Expand Serial Command Functional Specifications 8.5.10. CF_MODESTORE Command Command “CF_MODESTORE_%1” [CR] “1” -------------------- Store current Display adjust status to Mode1 “2” -------------------- Store current Display adjust status to Mode2 “3” -------------------- Store current Display adjust status to Mode3 “4” -------------------- Store current Display adjust status to Mode4 “5”...
  • Page 22: Input Control Command

    PLV-HD2000 Expand Serial Command Functional Specifications 8.6. Input Control Command 8.6.1. CF_INPUT Command Command “CF_INPUT_%1” [CR] “1” ------------ Select Input 1 “2” ------------ Select Input 2 “3” ------------ Select Input 3 “4” ------------ Select Input 4 Select Input (valid only when it is in the normal Power ON status) Details The same operation as “INPUT1”-“INPUT4”...
  • Page 23 PLV-HD2000 Expand Serial Command Functional Specifications 8.6.3. CF_INPUT1~4 Command Command “CF_INPUT1_%1_%2” [CR] “1” ----------------------------- Specify Input 1 “2” ----------------------------- Specify Input 2 “3” ----------------------------- Specify Input 3 “4” ----------------------------- Specify Input 4 “DIGITAL” -------------------- Select DVI Digital Input for computer “ANALOG”...
  • Page 24 PLV-HD2000 Expand Serial Command Functional Specifications 8.6.4. CF_SYSTEM Command Command “CF_SYSTEM_%1” [CR] “VGA1” -------------------------------- Select VGA1 “VGA2” -------------------------------- Select VGA2 Input is “D-WXGA3” -------------------------- Select D-WXGA3 “D-WXGA4” -------------------------- Select D-WXGA4 “MODE16” – “MODE20”----------- Select MODE16-20 “EXST21” – “EXT60” -------------- Select EXST21-60 “AUTO”...
  • Page 25: Screen Control Command

    PLV-HD2000 Expand Serial Command Functional Specifications 8.7. Screen Control Command 8.7.1. CF_SCREEN Command Command “CF_SCREEN_%1” [CR] “NORMAL” ----------------------------- Select Normal mode “FULL” ----------------------------------- Select Full mode “ANAMORPHIC” ---------------------- Select Anamorphic mode Select Screen size (valid only when it is in the normal Power ON status) Details The selected screen setting is stored even after main Power is turned OFF.
  • Page 26 PLV-HD2000 Expand Serial Command Functional Specifications 8.7.4. CF_HSCALE Command Command “CF_HSCALE_%1” [CR] “032” ----------------------------- +32 “031” ----------------------------- +31 “002” ----------------------------- +2 “001” ----------------------------- +1 “000” ----------------------------- +/-0 “-01” ----------------------------- -1 “-02” ----------------------------- -2 “-31” ----------------------------- -31 “-32” ----------------------------- -32 “UP” ----------------------------- Increment H Scale setting value by 1 “DN”...
  • Page 27: Lamp Command

    PLV-HD2000 Expand Serial Command Functional Specifications 8.8. Lamp Command 8.8.1. CF_LAMPH Command “CF_LAMPH_%1” [CR] Command “RSTn” (n=1-4) ----------------------------- Reset running time for Lamp 1-4 Reset Lamp 1-4 running time Details (valid only when it is in the normal Power ON status) Acceptable “000”...
  • Page 28: Setting Command

    PLV-HD2000 Expand Serial Command Functional Specifications 8.9. Setting Command 8.9.1. CF_BBACK Command Command “CF_BBACK_1” [CR] “ON” ----------------------------- Set Blue Back to ON “OFF” --------------------------- Set Blue Back to OFF Set/Cancel Blue Back (valid only when it is in the normal Power ON status) Details The status set by this command is stored in EEPROM of the projector, so its setting is effective even after the power is turned to ALL OFF.
  • Page 29 PLV-HD2000 Expand Serial Command Functional Specifications 8.9.5. CF_REAR Command Command “CF_REAR_%1” [CR] “ON” ----------------------------- Set Rear to ON “OFF” --------------------------- Set Rear to OFF Set/Cancel Rear (valid only when it is in the normal Power ON status) When Rear is ON, the image is left/right reversed. Details The status set by this command is stored in EEPROM of the projector, so its setting is effective even after the power is turned to ALL OFF status.
  • Page 30 PLV-HD2000 Expand Serial Command Functional Specifications 8.9.9. CF_P-MANE Command Command “CF_P-MANE_%1” [CR] “OFF” ----------------------------- Set Power management to OFF “READY” ------------------------- Set Power management to Ready “SHUTDOWN” ----------------- Set Power management to Shut Down Set/Cancel Power management (valid only when it is in the normal Power ON status).
  • Page 31 PLV-HD2000 Expand Serial Command Functional Specifications 8.9.13. CF_FDEFAULT Command Command “CF_FDEFAULT_%1” [CR] “RST” Set Factory Default setting values (valid only when it is in the normal Power ON Details status) Acceptable “000” [CR] Response Unacceptable “Error Code” [CR] 31/56...
  • Page 32: Status Read Command

    PLV-HD2000 Expand Serial Command Functional Specifications 9. Status Read Command 9.1. Format PC issues a command in the format below: “CR_ Command” [CR] Command: String When a projector receives the applicable command, it returns required data as a string. “000_” %1 [CR] %1: Required data (String.
  • Page 33: Image Status Read Command

    PLV-HD2000 Expand Serial Command Functional Specifications 9.3. Image Status Read Command 9.3.1. CR_BRIGHT Command Command “CR_BRIGHT” [CR] Details Get value of Brightness Acceptable “000_%1” [CR] Response “000” – “063” Unacceptable “Error Code” [CR] 9.3.2. CR_CONT Command Command “CR_CONT” [CR] Details Get value of Contrast Acceptable “000_%1”...
  • Page 34 PLV-HD2000 Expand Serial Command Functional Specifications 9.3.7. CR_WBAL-R Command Command “CR_WBAL-R” [CR] Details Get Red value of White Balance Acceptable “000_%1” [CR] Response “000” – “063” Unacceptable “Error Code” [CR] 9.3.8. CR_WBAL-G Command Command “CR_WBAL-G” [CR] Details Get Green value of White Balance Acceptable “000_%1”...
  • Page 35 PLV-HD2000 Expand Serial Command Functional Specifications 9.3.11. CR_NZRED Command Command “CR_NZRED” [CR] Details Get setting status of Noise Reduction Acceptable “000_%1” [CR] “OFF” -------------------------- Noise Reduction is set to OFF “L1” ----------------------------- Noise Reduction is set to L1 Response “L2” ----------------------------- Noise Reduction is set to L2 “L3”...
  • Page 36: Display Status Read Command

    PLV-HD2000 Expand Serial Command Functional Specifications 9.3.15. CR_APCTRL Command Command “CR_APCTRL” [CR] Details Get setting status of Auto Picture Control Acceptable “000_%1” [CR] “L1” ---------------------- Auto Picture Control is operated with Level 1 Response “L2” ---------------------- Auto Picture Control is operated with Level 2 “OFF”...
  • Page 37 PLV-HD2000 Expand Serial Command Functional Specifications 9.4.4. CR_H-POS Command Command “CR_H-POS” [CR] Details Get value of Horizontal Position Acceptable “000_%1” [CR] “0000” – “nnnn” Input is Computer (nnnn = Total Dots - Display Dots -1) Response Input is Video “0000” – “4095” Unacceptable “Error Code”...
  • Page 38: Status Read Command For Video

    PLV-HD2000 Expand Serial Command Functional Specifications 9.4.8. CR_ORGMODE Command Command “CR_ORGMODE” [CR] Get the original signal of the currently selected Mode set in Display adjust menu Details When MODE1-20 or EXT21-60 is not selected, get the current signal. Acceptable “000_%1” [CR] “XGA1”...
  • Page 39: Input Status Read Command

    PLV-HD2000 Expand Serial Command Functional Specifications 9.6. Input Status Read Command 9.6.1. CR_INPUT Command Command “CR_INPUT” [CR] Details Get selected Input No. Acceptable “000_%1” [CR] Response “1” – “4” Unacceptable “Error Code” [CR] 9.6.2. CR_SOURCE Command Command “CR_SOURCE” [CR] Details Get selected Source Acceptable “000_%1”...
  • Page 40 PLV-HD2000 Expand Serial Command Functional Specifications 9.6.3. CR_SRCINP1 Command Command “CR_SRCINP1” [CR] Details Get Source of Input 1 Acceptable “000_%1” [CR] “DIGITAL” ------------------ DVI Digital Input is selected “ANALOG” ----------------- Analog Input is selected “VIDEO” ---------------------------- Video Input is selected “S-VIDEO”...
  • Page 41 PLV-HD2000 Expand Serial Command Functional Specifications 9.6.7. CR_SYSTEM Command Command “CR_SYSTEM” [CR] Details Get selected System Acceptable “000_%1” [CR] “VGA1” ----------------------------------- VGA1 is selected “VGA2” ----------------------------------- VGA2 is selected Input is “D-WXGA3” ----------------------------- D-WXGA3 is selected “D-WXGA4” ----------------------------- D-WXGA4 is selected “MODE16”...
  • Page 42 PLV-HD2000 Expand Serial Command Functional Specifications 9.6.8. CR_SYSLIST Command Command “CR_SYSLIST” [CR] Details Get possible systems in the list Acceptable “000_%1_%2_ • • • _%x” [CR] (e.g.) “AUTO” ----------------------------- Auto is in the list “NTSC” ----------------------------- NTSC is in the list Response “108060 ---------------------------- 1080i60Hz is in the list “575I”...
  • Page 43 PLV-HD2000 Expand Serial Command Functional Specifications 9.6.12. CR_NMSLOT2 Command Command “CR_NMSLOT2” [CR] Details Get a slot board name inserted to Input 2 Acceptable “000_%1” [CR] Response The same data as CF_NMSLOT1 Unacceptable “Error Code” [CR] 9.6.13. CR_NMSLOT3 Command Command “CR_NMSLOT3” [CR] Details Get a slot board name inserted to Input 3 Acceptable...
  • Page 44 PLV-HD2000 Expand Serial Command Functional Specifications 9.6.16. CR_IDSLOT2 Command Command “CR_IDSLOT2” [CR] Get ID information of Input 2. This command is used to recognize the inserted Details board and specify the valid input source. Acceptable “000_%1” [CR] Response THE SAME AS CR_IDSLOT1 Unacceptable “Error Code”...
  • Page 45: Screen Status Read Command

    PLV-HD2000 Expand Serial Command Functional Specifications 9.7. Screen Status Read Command 9.7.1. CR_SCREEN Command Command “CR_SCREEN” [CR] Details Get currently selected screen image mode Acceptable “000_%1” [CR] “NORMAL” ---------------------------- Normal mode Response “FULL” ---------------------------------- Full mode “ANAMORPHIC” --------------------- Anamorphic mode Unacceptable “Error Code”...
  • Page 46: Lamp Status Read Command

    PLV-HD2000 Expand Serial Command Functional Specifications 9.8. Lamp Status Read Command 9.8.1. CR_LAMPREPL Command Command “CR_LAMPREPL” [CR] Details Get the information of Lamp Replacement time Acceptable “000_%1” [CR] “4****” 4 -------- indicates it is 4-lamp model. * -------- indicates the status of each lamp orderly. ”Y” means it is over the lamp replacement time, and “N”...
  • Page 47 PLV-HD2000 Expand Serial Command Functional Specifications 9.8.4. CR_LAMPSTS Command Command CR_LAMPSTS” [CR] Details Get the information of Lamp status Acceptable “000_%1” [CR] “4****” The first character indicates the model is 4-lamp system. The following characters indicates the lamp status as below: “I”...
  • Page 48: Setting Status Read Command

    PLV-HD2000 Expand Serial Command Functional Specifications 9.9. Setting Status Read Command 9.9.1. CR_BBACK Command Command “CR_BBACK” [CR] Details Get setting status of Blue Back Acceptable “000_%1” [CR] “ON” -------------------------- Blue Back is set to ON Response “OFF” ------------------------ Blue Back is set to OFF Unacceptable “Error Code”...
  • Page 49 PLV-HD2000 Expand Serial Command Functional Specifications 9.9.5. CR_LANG Command Command “CR_LANG” [CR] Details Get currently selected language Acceptable “000_%1” [CR] “ENG” --------------------------- English is selected “DEU” --------------------------- German is selected “FRA” ---------------------------- French is selected “ITA” ------------------------------ Italian is selected “ESP”...
  • Page 50 PLV-HD2000 Expand Serial Command Functional Specifications 9.9.9. CR_FANSPEED Command Command “CR_FANSPEED” [CR] Details Get currently selected Fan Control Speed Acceptable “000_%1” [CR] “MAX” -------------------------- Fan Control Speed is set to Max Response “NOR” -------------------------- Fan Control Speed is set to Normal Unacceptable “Error Code”...
  • Page 51: Other Status Read Command

    PLV-HD2000 Expand Serial Command Functional Specifications 9.10. Other Status Read Command 9.10.1. CR_PRESSURE Command Command “CR_PRESSURE” [CR] Get value from Air Pressure sensor Following is the formula to work out Air Pressure from the given value (“Vn” Details represents the value): Air Pressure (hPa) = (5*Vn / 1024 –...
  • Page 52 PLV-HD2000 Expand Serial Command Functional Specifications 9.10.5. CR_INFPFAIL Command Command “CR_INFPFAIL” [CR] Get the power failure status (Normal/Fail) at each check point. Data consists of HEX values with 48 bits. Power Failure checkpoints are 16 points in Main Unit, 8 in Sub Power Unit, 1 in Current Sensor, and 4 in Fan Sensor. For Main Unit and Sub Power Unit, each bit corresponds to their check points and Details indicates the status of “Normal/Abnormal”...
  • Page 53 PLV-HD2000 Expand Serial Command Functional Specifications 9.10.6. CR_TEMPWARN Command Command “CR_TEMPWARN” [CR] Get the information about the temperature inside the projector (close to/in the abnormal status, in the safe temerature level or sensor not detect abnormal Details temperature). It is possible to get the information about more than one sensors all at once if it is applicable.
  • Page 54: Command With Address Specification

    PLV-HD2000 Expand Serial Command Functional Specifications 10. Command with Address Specification 10.1. Overview - Commands with address are used to remote control more than one projectors through RS-232C by a computer. - The command with address is defined as a single command per line that starts with “A” and ends with carriage return (0x0D).
  • Page 55: Functional Execution Command With Address

    PLV-HD2000 Expand Serial Command Functional Specifications 10.2. Functional Execution Command with address Format 10.2.1. 1) PC issues a command in the format below: “A” Address “C” Command [CR] “A” Address “CF_” Command “_” Parameter [CR] Address: 3-digit number (”001” – “999”) Commands with “FFF”...
  • Page 56: Status Read Command With Address

    PLV-HD2000 Expand Serial Command Functional Specifications 10.3. Status Read Command with Address Format 10.3.1. 1) PC issues a command in format as below: “A” Address “CR” Command [CR] “A” Address “CR_” Command [CR] Address: 3-digit number (“001” – “999”) Command: string (Refer to Basic and Expand Serial Command) 2) The only projector with appropriate address decodes the received commands and returns the character line as the required data.

This manual is also suitable for:

Plv-hd2000

Table of Contents