2 Troubleshooting Procedures
Procedure 4
Replacement Check
The USB FDD or USB FDD cable may be defective or damaged. Replace it with a new one.
If the USB FDD is still not functioning properly, perform the following.
If USB port 0 does not work properly, perform check 1.
If USB port 6 does not work properly, perform check 3.
If eSATA/USB port 4 does not work properly, perform check 5.
Check 1
USB board may be faulty. Replace it with a new one following the steps in
Chapter 4, Replacement Procedures. If the problem still occurs, perform Check 2.
Check 2
USB board FFC may be faulty. Replace it with a new one following the steps in
Chapter 4, Replacement Procedures. If the problem still occurs, perform Check 5.
Check 3
Jack board may be faulty. Replace it with a new one following the steps in
Chapter 4, Replacement Procedures. If the problem still occurs, perform Check 4.
Check 4
Jack board FFC may be faulty. Replace it with a new one following the steps in
Chapter 4, Replacement Procedures. If the problem still occurs, perform Check 5.
Check 5
System board may be faulty. Replace it with a new one following the instructions
in Chapter 4, Replacement Procedures.