Power Supply Troubleshooting - Toshiba Portege A600 Maintenance Manual

Maintenance manual
Hide thumbs Also See for Portege A600:
Table of Contents

Advertisement

2 Troubleshooting Procedures
2.3

Power Supply Troubleshooting

The power supply controller controls many functions and components. To determine if the
power supply is functioning properly, start with Procedure 1 and continue with the other
Procedures as instructed. The procedures described in this section are:
Procedure 1: Power Status Check
Procedure 2: Error Code Check
Procedure 3: Connection Check
Procedure 4: Charging Check
Procedure 5: Replacement Check
Procedure 1
Power Status Check
The following icons indicate the power supply status:
Battery icon
DC IN icon
The power supply controller displays the power supply status with the Battery icon and the
DC IN icon as listed in the tables below.
Battery icon
Lights orange
Lights blue
Flashes orange
Blinks orange
(even intervals)
Blinks orange once
(at being switched on)
Doesn't light
2-8
[CONFIDENTIAL]
Table 2-1 Battery icon
Power supply status
Battery is charged and the external DC is input. It has no
relation with ON/OFF of the system power.
Battery is fully charged and the external DC is input. It has
no relation with ON/OFF of the system power.
Battery charge is low. The AC adaptor must be connected
to recharge the battery.
The battery level is low while the system power is ON.
The system is driven by only a battery and the battery level
is low.
Any condition other than those above.
PORTEGE A600 Maintenance Manual (960-710)
2.3 Power Supply Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents