Chassis Q-Fan Control [Disabled]
Allows you to enable or disable the chassis Q-fan control feature.
Configuration options: [Disabled] [Enabled]
The following item appears when you enable Chassis Q-Fan Control.
Chassis Fan Profile [Standard]
Allows you to set the appropriate performance level of the ASUS Q-Fan. When
set to [Standard], the chassis fan automatically adjusts depending on the chassis
temperature. Set this item to [Silent] to minimize fan speed for quiet chassis fan
operation, or [Turbo] to achieve maximum chassis fan speed. Configuration options:
[Standard] [Silent] [Turbo]
POWER FAN Control [Disabled]
Allows you to select the power fan control mode. When this item is set to
[Duty Mode], you can configure the Power Fan Duty item. If you set this item
to [Q-Fan Mode], you are allowed to configure the Power Fan Full Speed
Temp item. Configuration options: [Disabled] [Duty Mode] [Q-Fan Mode]
Power Fan Duty [50]
Allows you to set the fan duty cycle. This item appears when the POWER FAN
Control item is set to [Duty Mode].
Configuration options: [50] [60] [70] [80] [90] [100]
Power Fan Full Speed Temp [60˚C]
Allows you to set the temperature at which the power fan rotates at full speed.
This item appears when the POWER FAN Control item is set to [Q-Fan Mode].
Configuration options: [60˚C] [70˚C] [80˚C] 90˚C]
OPTFan1/2/3 Control [Disabled]
Allows you to select the optional fan control mode. When this item is set to
[Duty Mode], you can configure the OPTFan1/2/3 Duty item. If you set this
item to [Q-Fan Mode], you are allowed to configure the OPTFan1/2/3 Full
Speed Temp item.
Configuration options: [Disabled] [Duty Mode] [Q-Fan Mode]
You need to connect the thermal sensor cables to the OPT_TEMP1/2/3
connectors to enable this function.
OPTFan1/2/3 Duty [50]
Allows you to set the fan duty cycle. This item appears when the OPTFan1/2/3
Control item is set to [Duty Mode].
Configuration options: [50] [60] [70] [80] [90] [100]
OPTFan1/2/3 Full Speed Temp [60˚C]
Allows you to set the temperature at which the power fan rotates at full speed.
This item appears when the OPTFan1/2/3 Control item is set to [Q-Fan Mode].
Configuration options: [60˚C] [70˚C] [80˚C] 90˚C]