Instruction
branch (n)
a. Currently, patterns that use the sampled instruction are limited to the following format:
In the following table, x is the pattern number, y is the instruction number. Both x and
y need to be sequential. There are three categories of sound effect patterns: callProg
(call progress patterns), ringer and misc (miscellaneous).
Attribute
se.pat.callProg.x.name
se.pat.callProg.x.inst.y.type
se.pat.callProg.x.inst.y.value
se.pat.callProg.x.inst.y.param
88
Meaning
Advance n instruc-
tions and execute
that instruction (n
must be negative and
must not branch
beyond the first
instruction)
sampled followed by optional silence and optional branch back to the beginning.
Copyright © 2005 Polycom, Inc.
®
IP
Example
se.pat.callProg.x.inst.y.type = "branch" (branch instruc-
tion type)
se.pat.callProg.x.inst.y.value = "-5" (step back 5 instruc-
tions and execute that instruction)
Permitted Values
Interpretation
UTF-8 encoded
Used for identification purposes in the user inter-
string
face (currently used for ringer patterns only); for
patterns that use a sampled audio file which has
been overridden by a downloaded replacement, the
se.pat.ringer.x.name parameter will be overridden
in the user interface by the file names of the wave
file.
sampled OR chord
As above.
OR silence OR
branch
integer
Instruction type:
positive integer
If instruction type is chord, this optional parameter
specifies the on duration to be used, overriding the
on duration specified in the chord-set definition.
Optimization
Interpretation:
sampled
sampled audio file number
chord
chord set number
silence
silence duration in ms
branch
number of instructions to
advance