Dell PowerEdge M420 Reference Manual page 1418

Dell powerconnect m6220/m6348/m8024/m8024-k cli reference guide
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

Syntax
number variable interval
rmon alarm
value
[event-number]
direction
[startup
no rmon alarm
Syntax Description
Parameter
number
variable
interval
rising-threshold
value
falling-threshold
value
event-number
delta
absolute
1414
RMON Commands
falling-threshold value
]
number
Description
The alarm index. (Range: 1–65535)
A fully qualified SNMP object identifier that resolves to a
particular instance of a MIB object.
The interval in seconds over which the data is sampled and
compared with the rising and falling thresholds. (Range: 1–
2147483647)
Rising Threshold value. (Range: -2147483648 – 2147483647)
Falling Threshold value. (Range: -2147483648 – 2147483647)
The index of the Event that is used when a rising or falling
threshold is crossed. (Range: 1- 65535)
The sampling method for the selected variable and calculating
the value to be compared against the thresholds. If the method
is delta, the selected variable value at the last sample is
subtracted from the current value, and the difference compared
with the thresholds.
The sampling method for the selected variable and calculating
the value to be compared against the thresholds. If the method
is absolute, the value of the selected variable is compared
directly with the thresholds at the end of the sampling interval.
{delta | absolute}
[event-number] [owner
rising-threshold
string
]

Hide quick links:

Advertisement

Table of Contents
loading