designed for you to specify whether or not ISP domain names are carried in the usernames to be
sent to the RADIUS server.
For a RADIUS scheme, if you have specified to exclude ISP domain names from usernames, you
should not use this RADIUS scheme in more than one ISP domain. Otherwise, such errors may
occur: the RADIUS server regards two different users having the same name but belonging to
different ISP domains as the same user (because the usernames sent to it are the same).
For an 802.1x user, if you have specified to use EAP authentication, the switch will encapsulate
and send the contents from the client directly to the server. In this case, the configuration of the
user-name-format command is not effective.
Related commands: radius scheme.
Examples
# Specify to exclude ISP domain names from the usernames to be sent to RADIUS server in RADIUS
scheme radius1.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] radius scheme radius1
New Radius scheme
[Sysname-radius-radius1] user-name-format without-domain

HWTACACS Configuration Commands

data-flow-format

Syntax
data-flow-format data { byte | giga-byte | kilo-byte | mega-byte }
data-flow-format packet { giga-packet | kilo-packet | mega-packet | one-packet }
undo data-flow-format { data | packet }
View
HWTACACS scheme view
Parameters
data: Sets the data unit of outgoing HWTACACS data flows, which can be byte, giga-byte,
kilo-byte, or mega-byte.
packet: Sets the packet unit of outgoing HWTACACS data flows, which can be one-packet,
giga-packet, kilo-packet, or mega-packet.
Description
Use the data-flow-format command to set the units of data flows to TACACS servers.
Use the undo data-flow-format command to restore the default units.
By default, the data unit and packet unit for outgoing HWTACACS flows are byte and one-packet
respectively.