Checking The Input Voltage; Clearing All Memory Settings - Brother BAS-343E Instruction Manual

E series programmable electronic pattern sewer
Hide thumbs Also See for BAS-343E:
Table of Contents

Advertisement

9-14. Checking the input voltage

1. Turn on the power switch.
2. Press the menu switch q until the X-SCALE indicator w illuminates.
SPLIT N .
q
3. While pressing the TEST switch e, press the R/W switch r.
TEST
TEST
e\
4. If the input voltage is normal, the input voltage conditions will be shown in the display as indicated at right.
200-V specifications
220-V specifications
230-V specifications
100-V, 380-V, 400-V and
415-V specifications
5. Press the TEST switch e once more to return the display to the normal condition.

9-15. Clearing all memory settings

• If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have
been made by means of the memory switch, for instance. In such cases, carry out the following procedure to
clear the memory, and also check the DIP switch settings.
While pressing the R/W switch, turn on the power. This will clear all of the memory setting.
R / W
X - SCALE
w
R / W
r
090
110
"100" is displayed when the input voltage is 200 V.
100
120
105
125
"110" is displayed when the input voltage is
100 V (for 100-V specs.), 380 V (for 380-V specs.)
100
120
or 415 V (for 415-V specs.).
BAS-343E
9. Standard adjutsments
41

Advertisement

Table of Contents
loading

Table of Contents