9. Standard adjustments
9-6. Adjusting the movable knife
Needle
Plate
Loosen the nut w and move thread trimmer rod L e to the left or right to adjust so that the V section A of the movable
knife q is aligned with the index mark B on the needle plate when the machine is at the stop position.
Replacing the movable and fixed knives
34
1. Remove screws q and w, and needle plate e. Now
disconnect the thread cutter connecting rod r from
stud t.
BAS-343E