Checking The Input Voltage; Clearing All Memory Settings - Brother KE-434C Instruction Manual

Electronic lockstitch pattern tacker electronic lockstitch pattern tacker with stepping foot
Hide thumbs Also See for KE-434C:
Table of Contents

Advertisement

10. STANDARD ADJUSTMENTS

10-13. Checking the input voltage

Specifications
200V
220V
230V
100V
380V
400V
415V
1. Turn on the power switch.
2. Press the SELECT switch (1) until the Y-SCALE indicator (2) illuminates.
3. While pressing the TEST switch (3), press the RESET switch (4).
4. If the input voltage is normal, the input voltage conditions will be shown in the display window (5) as indicated in the table above.
5. Press the TEST switch (3) again to return the display to the normal condition.

10-14. Clearing all memory settings

If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have been made by means
of the memory switch, for instance. In such cases, carry out the following procedure to clear the memory, and also check the DIP
switch settings.
[ Method ]
While pressing the RESET switch, turn on the power. This will clear all of the memory setting.
Note:
This operation causes memory switches to be returned to their initial settings, and user program setting to be cleared.
46
Display
[090 - 110]
[100 - 120]
"100" is displayed when the input voltage is 200 V.
[105 - 125]
"110" is displayed when the input voltage is
[100 - 120]
100V (for 100-V specs), 380V (for 380-V specs),
400V (for 400-V specs) or 415V (for 415-V specs).
Notes
KE-434C,435C
2582Q

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ke-435c

Table of Contents