Snmp Group Table Settings - D-Link DGS-3120-24TC Product Manual

Product manual
Hide thumbs Also See for DGS-3120-24TC:
Table of Contents

Advertisement

xStack® DGS-3120 Series Managed Switch Web UI Reference Guide
The fields that can be configured are described below:
Parameter
Community Name
View Name
Access Right
Click the Apply button to accept the changes made.
Click the Delete button to remove the specific entry.

SNMP Group Table Settings

An SNMP Group created with this table maps SNMP users (identified in the SNMP User Table) to the views
created in the previous window.
To view the following window, click Management > SNMP Settings > SNMP Group Table Settings, as show
below:
Figure 3–37 SNMP community Table Settings window
Description
Type an alphanumeric string of up to 32 characters that is used to identify members of
an SNMP community. This string is used like a password to give remote SNMP
managers access to MIB objects in the Switch's SNMP agent.
Type an alphanumeric string of up to 32 characters that is used to identify the group of
MIB objects that a remote SNMP manager is allowed to access on the Switch. The view
name must exist in the SNMP View Table.
Read Only – Specify that SNMP community members using the community string
created can only read the contents of the MIBs on the Switch.
Read Write – Specify that SNMP community members using the community string
created can read from, and write to the contents of the MIBs on the Switch.
49