The portLogClear command clears the data from the port log. The command syntax
is

portLogClear.

The portLogDump command prints the port log without page breaks. The command
syntax is

portLogDump.

The portStatsShow command, when used with a port number, gives a static view of
the port status when the switch executed the command. For example, to update the
command and check if an error count is increasing, reissue the portStatsShow com-
mand to capture another snapshot. Fields for the portStatsShow command are
described in Table 4-15.
The command syntax is portStatsShow <port #>.
   
Encoding errors inside of frames
Frames with cyclic redundancy check (CRC)
errors
Frames shorter than minimum
Frames longer than maximum
Frames with bad end-of-frame delimiters
Encoding error outside of frames
Class 3 frames discarded
Link failures (LF1 or LF2 states)
Loss of synchronization
Loss of signal
Frames rejected with F_RJT
Frames busied with F_BSY