support.dell.com
MIB-II system group, interface group, and SNMP group
 
Vendor-Specific MIBs
Standard Generic traps
Enterprise-Specific traps
NOTES: You must configure the management platform's IP address as a trap recipient
so it will be discovered by that management platform. HP OpenView NNM SE version
3 and above have MIB and auto discovery support for the switch.
While the switch may be managed using a MIB browser, Dell recommends using the
web-based PowerVault 56F Switch Manager or using the Telnet command.
The SNMP manage node residing on the embedded processor supports UDP/IP over
the Ethernet interface or any FC-IP interface (see Table 3-1). This transport provides
an immediate Plug and Play support for the switch once the IP address has been
assigned.
The following five object groups are defined and supported:
Configuration group
Operation group
Error group
Accounting group
Capability group
The agent supports all groups, except the accounting group, which is better sup-
ported in the Fibre Channel Port (FCP) group of the vendor-unique MIB.
The following five groups of MIBs are defined and supported:
PowerVault 56F system group
Fabric group
SNMP manage node configuration group
FCP group
Name server group
Managing the PowerVault 56F 16-Port Fibre Channel Switch