4-16
Installation and Troubleshooting Guide
The errShow command displays all detected errors, one error at a time. The error log
stores the last 32 error types sensed by the switch. The log shows:
Error number (01-64)
Date and time of the first occurrence each error type was sensed
Total number of occurrences of each error type
NOTE: The maximum number of occurrences is 999.
Error type
— Error level for each error type
— 0 = Panic (when this level is reached, the switch automatically reboots and
the display no longer shows the error)
— 1 = Critical
— 2 = Error
— 3 = Warning
— 4 = Debug
For a detailed explanation of each error type, its probable cause, and suggested cor-
rective actions, see Appendix A, "Error Messages."
The following information is displayed in the errShow screen:
The switch detected two errors.
The task ID and task name that incurred the error (task names are displayed
using the i command). For example,
The error type, date and time, the error level, and description.
— If there is more than one occurrence of an error type, the number of occur-
rences is shown in brackets following the error date and time.
The following is an example of the errShow command screen.
.