Dell PowerVault 50F Installation And Troubleshooting Manual page 101

Dell powervault 56f 16-port fibre channel switch installation and troubleshooting guide
Hide thumbs Also See for PowerVault 50F:
Table of Contents

Advertisement

support.dell.com
% &"
   
No light showing
Power not applied.
Steady power LED
Normal power-on indicator.
Flashing power
Switch failed POST and is not functioning, although power is
LED
applied.
The color and flash speed of each port's LED, as described in Table 5-2, indicates the
individual port's status.
% &"
   
No light showing
No light or signal carrier (no module, no cable) for media
interface LEDs
Steady yellow
Receiving light or signal carrier, but not yet online
Slow yellow
Disabled (result of diagnostics or portDisable command);
flashes every 2 seconds
Fast yellow
Error, fault with port; flashes every 1/2 second
Steady green
Online (connected with device over cable)
Slow green
Flashes every 2 seconds; interswitch link; the port is physi-
cally online, but the fabric remains segmented due to an
incompatable switch or switch firmware
Fast green
Internal loopback (diagnostic); flashes every 1/2 second
Flickering green
Online and frames flowing through port
At power-on or reset, the following steps are executed:
1.
Preliminary POST diagnostics.
2.
VxWorks operating system initialization.
3.
Hardware initialization (resets, internal addresses assigned to G_Port and FL_Port
ASICs, serial port initialized, front panel initialized).
4.
Full POST.
5.
Universal port configuration.
6.
Link initialization; receiver/transmitter negotiation to bring connected ports online.
Troubleshooting
5-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault 51fPowervault 56f

Table of Contents